Buy more than* S$200* and get FREE SHIPPING

Meter Relay K3MA-J

Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Allowable Voltage Range
85-110% of the supply voltage
Vibration Resistance
Frequency: 10 to 55Hz, acceleration: 50m / s 2 X, Y, Z each direction 5min x 10 sweep
Polar Display
When negative, the input signal is automatically - Table view the ""
EMC Standard
EN61326 + A1 industrial applications static: EMI: EN61326 + A1 industrial applications radiated disturbance field strength: CISPR 11 Group 1, Class A noise terminal voltage: 1, Class A EMS CISPR 11 Group discharge immunity: EN61000-4-2 electromagnetic fie
Safety Standards
2 / Overvoltage category Pollution degree II: UL3121-1, EN61010-1 (IEC61010-1)
Storage Temperature Range (degree c)
-25 to +65(No condensation, No freezing)
Ambient Humidity
25-85% relative humidity (with no condensation)
Display Update Period
(Sampling period x average number of times the average processing function used) sampling period
Sampling Period
250ms
Protection Feature
(100,000 times the number of writes) non-volatile memory: memory
Input Impedance
Current input: 45ohm voltage input: 1Mohm or more
Operating Ambient Temperature (deg C)
-10 to +55(No condensation, No freezing)
Insulation Resistance (Mohm)
Case between the external terminals (at DC500V mega), more than 20 input - output - power between
Input Signal
(0 to 20mA, 4 to 20mA, 0 to 5V, 1 to 5V, +/- 5V, +/- 10V) DC current / voltage
Functions
Scaling function: Program method (Table show range conforms to the maximum display digit number) can be set arbitrarily hold function The position of the decimal point: MAX value hold (maximum value), MIN value hold (minimum value ) comparison output hyst
Display Part
7-segment digital table shows
Input
Type: DC voltage / DC current
Display
Zero: the high-order digits zero suppression
Body Weight (g)
About200
System
Measurement: double integration method
Withstand Voltage
(Case between the external terminals and) AC2000V more than 1min
Protection Structure
Front: NEMA4X Indoor compliant (IP66 equivalent) rear case: IP20 terminal area: IP00 + finger protection (VDE0106 / 100)
...see all>
Product Options
ADD TO CART
Power Supply Voltage (V) Display Digit Response Time Impact Resistance (m/s2) Restriction Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
Power Supply Voltage (V) Display Digit Response Time Impact Resistance (m/s2) Restriction Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
AC100 to 240(50/60Hz) - - 3 times each in 6 150 3-axis direction   1PC 1 K3MA-J AC100-240V 08587634 349.90 SGD
In stock
AC24 (50 / 60Hz), (no polarity) DC24 - - 3 times each in 6 150 3-axis direction   1PC 1 K3MA-J AC/DC24V 08587643 349.90 SGD
In stock
AC100 to 240(50/60Hz) : Up to 5 digits (-19999 to 99999) Comparison output: 750ms or less 3 times each in 6 100 3-axis direction   1PC 1 K3MA-J-A2 AC100-240V 08587652 409.90 SGD
Shipped after 2017-11-27
AC24 (50 / 60Hz), (no polarity) DC24 - Comparison output: 750ms or less 3 times each in 6 100 3-axis direction *[No return] You cannot return this product. For details, see FAQ. 1PC 1 K3MA-J-A2 AC/DC24V 08587661 389.90 SGD
Shipped after 2017-11-27
ADD TO CART