ADA600F Series

Caution
This product is manufactured in Japanese standards. Please check the specification before you order., * Refer to derating curve since available load current become changed depends on natural convection cooling or forced draft.
Input format
Full range input
Over-Voltage Protection
31-34.5
Holding Time (ms)
20typ(ACIN 100V,Io=100%)
Ambient Temperature Difference (mV)
0 over + 50 degC 240max
Output Voltage Accuracy (V)
23.5-24.5
Starting Time (min)
500max(ACIN 100V,Io=100%)
Temporality Drift (mV)
96max
Ripple (mVp-p)
0 over + 50 degC 120max, over 10 over 0 degC 160max
Ripple Noise (mVp-p)
0 over + 50 degC 150max, over 10 over 0 degC 180max
Static load Variation (mV)
150max
Static Inputs Change (mV)
96max
Rated Input Efficiency (%)
ACIN 100V 84typ(Io=100%) ,ACIN 200V 86typ(Io=100%)
Overcurrent Protection
Operating at 101% min of peak current, automatic recovery
Rated Output Voltage (V)
24
Output Voltage Range (V)
21.6-27.0
Insulation Voltage
Input - Output / RC AC3000V 1min between the cut-off current = 10mA, DC500V 50Mohm min (room temperature) Input - FG AC2000V 1min between the cut-off current = 10mA, DC500V 50Mohm min (room temperature) output / RC over FG AC500V 1min between the cut-off current = 100mA, DC500V 50Mohm min (room temperature)
Inrush Current (A)
ACIN 100V 20typ (Io = 100%) (re-loading interval 3sec or more), ACIN 200V 40typ (Io = 100%) (re-loading interval 3sec more)
Input Frequency (Hz)
50/60(47-63) or DC
Alarm Output
Detecting a decrease in the input voltage (PF) / detecting a drop in the output voltage (LV)
Rated Output Power (W)
600
Power Factor
ACIN 100V 0.99typ(Io=100%),ACIN 200V 0.98typ(Io=100%)
Operating Temperature and Humidity Range
Over 10 over + 71 degC , 20 over 90% RH (no condensation)
Display Color
LED: green
Other Functions
Remote Control (RC) and power necessary for the drive to the external
Output Rating Current (Standard) (A)
ACIN 100V 14 (peak 25) natural air cooling, ACIN 100V 21 (peak 25) forced draft, ACIN 200V 15 (peak 31) natural air cooling, ACIN 200V 25 (peak 31) forced draft
Input Voltage (V)
AC85 over 264 1Phi or DC 120 over 350
Leak Current
0.75 max (60Hz, IEC60950, by each method of measuring the electric depreciation method) (Io = 100%)
Series
AD
...see all
Product Options
ADD TO CART
Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
Package
Qty.
Ship pack of Mfr.# Item.# Sales Price Availability Qty.
1PC 1 ADA600F-24 87007225 269.90 SGD
In stock
ADD TO CART