Buy more than* S$200* and get FREE SHIPPING

  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA

2 circuit limit switch WLCA WLCA12-2N

Item.#
02087093
Mfr.#
WLCA12-2N
Package Qty.
1PC
Ship pack of
1
69.70 SGD
ADD TO CART
In stock
Now we ship to...
...see all
Item Feature
Insulation Resistance (Mohm)
More than 100 (with DC500V mega)
Terminal Screws
4-M4
Mechanical Durability
More than 1500 million times
Impact Resistance (Malfunction)
More than 300 m/s2
Appliance Classes
classI
Ground Terminal
Without
Impact Resistance
More than 1000 m/s2
Force for Operating (OF) (N)
Maximum 9.61
Flowing Current (A)
10
Short Circuit Protection Installation
10A fuse gG or gI (IEC269) type
Electric Rating
Standard type
Contact Resistance (mohm)
25 or less (initial value)
Electrical Durability
More than 750,000
Switch
General internal switch 1a1b contact type
Weight (g)
About 275 (in the case of WLCA2 type)
Specification
Overtravel type
Inrush Current (A)
Normally-closed path: Maximum 30 Normally-opened path: Maximum 20
Caution
This product is manufactured in Japanese standards. Please check the specification before you order., This product is manufactured in Japanese standards. Please check the specification before you order.
Allowable Operating Speed
1 mm - 1 m/s (in the case of WLCA2 type)
Head Specification
(Single-sided operation), (head attachment) 2 directions are possible.
Degree of Contamination (Uise Environment)
3(EN60947-5-1)
Rated Enclosed Thermal Current
10A, 0.5A(EN60947-5-1)
Conditional Short Circuit Current
100A(EN60947-5-1)
Return Force (N)
Reference Value RF(minimum): 1.18
Vibration Resistance (malfunction)
10 to 55Hz 1.5mm frequency
Ambient Humidity
35 - 95%RH
Type
Standard type
Rated Frequency (Hz)
50/60
Environmental Information
Standard type
Rated Insulation Voltage (V)
(Ui)250(EN60947-5-1)
Protection Structure
IP67
TRUSCO Part Number
102-1613
Actuator Type
Adjustable roller, lever type (overrun type 90degree movement type)
Differential Travel
Reference value: MD (maximum): 12degree
Opreration
Reference value Movement until motion PT: Maximum 20degree Movement after motion OT (Minimum): 70degree
Operation Indicator
Not available
Operating Ambient Temperature (deg C)
-10 to 80 (however, no freezing)
Allowable Operating Frequency
Mechanical: 120 rounds/min Electrical: 30 times/min
Withstand Voltage
Homopolar terminal spacing: AC600V 50/60Hz 1min Between each terminal and earth:AC1500V 50/60Hz 1min/Uimp 2.5kV Between each terminal and non-charging metal:AC1500V 50/60Hz 1min/Uimp 2.5kV