Buy more than* S$200* and get FREE SHIPPING

  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA
  • 2 circuit limit switch WLCA

2 circuit limit switch WLCA WLCA12-2N

Item.#
02087093
Mfr.#
WLCA12-2N
Package Qty.
1PC
Ship pack of
1
69.69 SGD
ADD TO CART
In stock
Now we ship to...
...see all
Item Feature
Rated Insulation Voltage (V)
(Ui)250(EN60947-5-1)
Environmental Information
Standard type
Electric Rating
Standard type
Electrical Durability
More than 750,000
Degree of Contamination (Uise Environment)
3(EN60947-5-1)
Rated Enclosed Thermal Current
10A, 0.5A(EN60947-5-1)
Terminal Screws
4-M4
Impact Resistance (Malfunction)
More than 300 m/s2
Appliance Classes
classI
Ground Terminal
Without
Operation Indicator
Not available
Rated Frequency (Hz)
50/60
Type
Standard type
Withstand Voltage
Homopolar terminal spacing: AC600V 50/60Hz 1min Between each terminal and earth:AC1500V 50/60Hz 1min/Uimp 2.5kV Between each terminal and non-charging metal:AC1500V 50/60Hz 1min/Uimp 2.5kV
Switch
General internal switch 1a1b contact type
Differential Travel
Reference value: MD (maximum): 12degree
Specification
Overtravel type
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Operating Ambient Temperature (deg C)
-10 to 80 (however, no freezing)
Head Specification
(Single-sided operation), (head attachment) 2 directions are possible.
Short Circuit Protection Installation
10A fuse gG or gI (IEC269) type
Protection Structure
IP67
TRUSCO Part Number
102-1613
Contact Resistance (mohm)
25 or less (initial value)
Insulation Resistance (Mohm)
More than 100 (with DC500V mega)
Mechanical Durability
More than 1500 million times
Conditional Short Circuit Current
100A(EN60947-5-1)
Return Force (N)
Reference Value RF(minimum): 1.18
Vibration Resistance (malfunction)
10 to 55Hz 1.5mm frequency
Ambient Humidity
35 - 95%RH
Force for Operating (OF) (N)
Maximum 9.61
Impact Resistance
More than 1000 m/s2
Flowing Current (A)
10
Actuator Type
Adjustable roller, lever type (overrun type 90degree movement type)
Opreration
Reference value Movement until motion PT: Maximum 20degree Movement after motion OT (Minimum): 70degree
Weight (g)
About 275 (in the case of WLCA2 type)
Inrush Current (A)
Normally-closed path: Maximum 30 Normally-opened path: Maximum 20
Allowable Operating Frequency
Mechanical: 120 rounds/min Electrical: 30 times/min
Allowable Operating Speed
1 mm - 1 m/s (in the case of WLCA2 type)