Buy more than* S$200* and get FREE SHIPPING

  • Double-Circuit Limit-Switch WLG
  • Double-Circuit Limit-Switch WLG
  • Double-Circuit Limit-Switch WLG
  • Double-Circuit Limit-Switch WLG

Double-Circuit Limit-Switch WLG WLG12

3.67 (3)
Item.#
02087197
Mfr.#
WLG12
Package Qty.
1PC
Ship pack of
1
84.36 SGD
ADD TO CART
In stock
Now we ship to...
...see all
Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Appliance Classes
class[I]
Electrical Durability
Above 500,000 times
Return Force (N)
Reference Value RF(Minimum): 0.98
Contact Resistance (mohm)
Below 25 (initial value)
Type
Standard type
Force for Operating (OF) (N)
Maximum 9.81
Mechanical Durability
10,000,000 times or more
Impact Resistance (Malfunction)
Above 300m/s2
Degree of Contamination (Uise Environment)
3(EN60947-5-1)
Rated Frequency (Hz)
50/60
Operation Indicator
None
Conditional Short Circuit Current
100A(EN60947-5-1)
Rated Insulation Voltage (V)
(Ui)250(EN60947-5-1)
Opreration
Reference value, movement until operation PT: 10degree (-1 to +2degree) movement after operation OT (Minimum):65degree
Inrush Current (A)
Regular closed circuit: Maximum 15 Regular open circuit: Maximum 10
Actuator Type
Adjustable roller lever type (Opato label, high sensitivity type / 80degree)
Switch
General internal switch, 1a1b contact type
Allowable Operating Speed
1 mm to 1 m/s (in the case of WLCA2 type)
Impact Resistance
Above 1000 m/s2
Environmental Information
Standard type
Electric Rating
Standard type
Protection Structure
IP67
Ground Terminal
None
Operating Ambient Temperature (deg C)
-10 to 80 (but no freezing)
TRUSCO Part Number
102-1591
Insulation Resistance (Mohm)
100 or more (for DC500V meggers)
Terminal Screws
4-M4
Vibration Resistance (malfunction)
10 to 55 Hz, double amplitude of 1.5mm
Rated Enclosed Thermal Current
10A, 0.5A(EN60947-5-1)
Flowing Current (A)
10
Ambient Humidity
35 - 95%RH
Short Circuit Protection Installation
10A fuse shape, gG or gI (IEC269)
Withstand Voltage
Homopolar terminal spacing: AC6000V 50/60Hz 1min Between each terminal and earth: AC1500V 50/60Hz 1min/Uimp 2.5kV Between each terminal and non-charging metal: AC1500V 50/60Hz 1min/Uimp 2.5kV
Differential Travel
Reference value: MD(Maximum): 7degree
Head Specification
(Single-sided operation)x, (head attachment) 4 -way movement possible
Allowable Operating Frequency
Mechanical: 120 times/min Electrical: 30 times/min
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 1
Review Rating: 3.67
3 Customer Reviews
The reviews are automatic translation.
Maintenance of machinery
5
From Japan
On 2016-07-29 18:43:51
I bought several times. You can use without any problems.
This review is about item#02087197.
Machinery maintenance
1
From Japan
On 2013-06-06 10:23:01
Nothing use impressions, this screen with the drawing of the variable roller type, had arrived arrived not a "variable". I wonder if it is not unkind. And not returned, wonder what about.
This review is about item#35459742.
Repairs to the machine
5
From Japan
On 2013-01-27 15:20:01
It was used for the repair of the machine. It could be used without having to worry about because it was brand item. SMC There is a picture in preparation products such as commodity because it is welcome if it is possible to display just shape.
This review is about item#35459943.