NoteBuy more than* S$200* and get FREE SHIPPING

  • 2-Circuit Limit-Switch WLH-
  • 2-Circuit Limit-Switch WLH-
  • 2-Circuit Limit-Switch WLH-
  • 2-Circuit Limit-Switch WLH-

2-Circuit Limit-Switch WLH- WLHAL4

5.00 (2)
Item.#
02087251
Mfr.#
WLHAL4
Package Qty.
1PC
Ship pack of
1
Restriction
*[No return] You cannot return this product. For details, see FAQ.
69.69 SGD
ADD TO CART
Shipped after 2016-12-16
Now we ship to...
...see all
Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Degree of Contamination (Uise Environment)
3(EN60947-5-1)
Environmental Information
Standard Type
Rated Frequency (Hz)
50/60
Protection Structure
IP67
Insulation Resistance (Mohm)
More than 100 (at DC500V mega)
Flowing Current (A)
10
Impact Resistance (Malfunction)
300m / s 2 more
Vibration Resistance (malfunction)
10 to 55Hz double amplitude 1.5mm
Rated Enclosed Thermal Current
10A,0.5A(EN60947-5-1)
Type
Standard type
Impact Resistance
1000m / s 2 more
Appliance Classes
classI
Electrical Durability
750000 times or more
Operating Ambient Temperature (deg C)
(No freezing) -10 to 80
Inrush Current (A)
(break contact) up to 30, (make contact) up to 20
Allowable Operating Frequency
Mechanical: 120 times / min Electrical: 30 times / min
Head Specification
(Unilateral action) x, (head mounted) four directions possible
Actuator Type
Adjustable rod lever type (overtravel type general form 80 degree 350 to 380mm)
Ground Terminal
None
Conditional Short Circuit Current
100A(EN60947-5-1)
Terminal Screws
4-M4
Rated Insulation Voltage (V)
(Ui)250(EN60947-5-1)
2014 TRUSCO Published Page
1-2448
Mechanical Durability
15 million times or more
Return Force (N)
Reference value RF (Min): 0.15
Force for Operating (OF) (N)
Max0.98
Operation Indicator
Nothing
Ambient Humidity
35 to 95%RH
Short Circuit Protection Installation
GI or 10A fuse type gG (IEC269)
TRUSCO Part Number
102-1583
Electric Rating
Standard Type
Contact Resistance (mohm)
25 or less (initial value)
Switch
General Built-in switch 1a1b contact form
Differential Travel
Reference values​​: MD (maximum): 12 degree
Allowable Operating Speed
(In the case of form WLCA2) 1mm to 1m / s
Withstand Voltage
AC2200V 50 / 60Hz 1min / Uimp 2.5kV: non-charging metal part between the 50 / 60Hz 1min / Uimp 2.5kV each terminal AC2200V: ground between the 50 / 60Hz 1min each terminal AC1000V: same extreme child between
Opreration
OT movement of 15 +/- 5 degree after operation (Min): PT movement to a reference value operations 55 degree
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
2 Customer Reviews
The reviews are automatic translation.
Advancement of the machine running, the reverse switching
5
From Japan
On 2016-02-24 16:14:53
It used outdoors with a roof but is operating without problems.
This review is about item#02087233.
Machine control
5
From Japan
On 2015-08-31 14:59:15
It can be used without comparable with elsewhere
This review is about item#02087276.