NoteBuy more than* S$150* and get FREE SHIPPING

  • Solid-State Timer H3CR-A

Solid-State Timer H3CR-A H3CR-A8E AC/DC24-48

4.43 (14)
H3CR-A8E AC/DC24-48
Package Qty.
Ship pack of
*[No return] You cannot return this product. For details, see FAQ.
Now we ship to...
...see all
Item Feature
Minimum Signal Input Time (sec)
Insulation Resistance (Mohm)
100 or more (by DC500V mega)
Time Specification
0.05s to 300h
Recovery Time
0.1s or less
Power Supply Voltage (V)
AC24 - 48 (50/60Hz) / DC24 - 48
Ambient Humidity
35 to 85%
Electrostatic Yield Strength
Malfunction: 8kV, destruction: 15kV
Input Method
This product is manufactured in Japanese standards. Please check the specification before you order.
Effect of Temperature
+/- (The 1% +/- 10ms or less +/- 1.2s, in 3s range) The following (a percentage of full scale) less than 1%
Time Base Range
4 stage switchable sec (seconds), min (minutes), hrs (time), selected from x 10h (time)
Operating Mode
Interval (Power Start) J:: A: ON-delay (power supply start) B2: (power start) E flicker on start one-shot output (power start)
Scale Type
Selected from the four-stage switchable 1.2,3,12,30
Control Output
(P level, reference value) (cosphi = 1) minimum applicable load DC5V 100mA AC250V/DC30 5A DC125V 0.15A resistance load
Storage Temperature Range (degree c)
-25 To 65 (with no freezing)
Impact Resistance
3 times each 1000m / s 2 6 direction
Contact output type 4 operating multi-
Voltage Influence
+/- (and 0.2% +/- 10ms or less +/- 1.2s, in 3s range) (As a percentage of full scale) 0.2% or less
(1800 times / h AC250V 5A resistive load switching frequency) 100,000 times or more: mechanical (no load, 1800 times / h switching frequency) electrical 20 million times or more
Power Reset
The minimum power-supply cut-off time 0.1s
Pin Type
Maximum Time Scale
Protection Structure
IP40 (panel surface portion)
Operating Temperature Range (deg C)
-10 To 55 (with no freezing)
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
Weight (g)
About 90
Output Type
Relay 2c (time-limit + instant)
Withstand Voltage
AC2000V 50/60Hz 1min contact between different poles:: AC2000V 50/60Hz 1min non-continuous contact between circuit operation between the AC2000V 50/60Hz 1min control output: non-current-carrying metal parts between the current-carrying metal parts : AC1000V 50/60Hz 1min
Allowable Voltage Range
85-110% of the supply voltage (DC12V is 90-110%)
Setting Time
Scale number: (in hours) 1.2: (sec) 0.05 - 1.2, (min, hrs) 0.12 - 1.2, (10h) 1.2 - 12 3: (sec, min, hrs) 0.3 - 3, (10h) 3 - 30 12: (sec, min, hrs) 1.2 - 12, (10h) 12 - 120 30: (sec, min, hrs) 3 - 30, (10h) 30 - 300
Noise Immunity
Square-wave noise by noise simulator (pulse width 100ns/1micros rise 1ns) +/- 1.5kV, however, +/- 600V is no voltage between the input terminals
Set Error
The +/- +/- 50ms or less (a percentage of full scale) 5%
Impact Resistance (Malfunction)
3 times each in 100m / s 2 6 direction
Vibration Resistance (malfunction)
10 - 55Hz single amplitude 0.5mm 3 each direction 10min
Impulse Voltage(V)
Non-current-carrying metal parts between the exposed and 3k conductive part terminal:: 4.5k between power supply terminals
Vibration Resistance
10 - 55Hz single amplitude 0.75mm 3 directions of the 2h
Operating Time Variation
+/- (and 0.2% +/- 10ms or less +/- 1.2s, in 3s range) The following (a percentage of full scale) 0.2% or less
Release Voltage
10% of the supply voltage
Power Consumption
Relay ON / OFF time: about 0.9W (DC24V time)
Customer Reviews
5 star 9
4 star 2
3 star 3
2 star 0
1 star 0
Review Rating: 4.43
14 Customer Reviews
The reviews are automatic translation.
Adding to the control panel
From Japan
On 2015-08-21 10:51:26
Mounting behavior was both good.
This review is about item#02490232.
Timer for industrial machinery
From Japan
On 2015-05-29 09:45:08
There is no particular trouble for the goods. Replacement in Discontinued products survive found. In addition, very survive even arrive the next day.
This review is about item#02490266.
Use the time limit of the drainage.
From Japan
On 2014-10-22 13:21:27
It went very well.
This review is about item#02490232.
From Japan
On 2014-10-10 16:14:05
Old goods and compatible There could be replaced soon
This review is about item#02490266.
B2 mode, intermittent air blow use
From Japan
On 2014-05-21 09:49:06
Cheaper price than the twin timer. Other 1) is good it is instantaneous contact in the interval mode. 2) power supply, start, the use of the gate I want to various thinking.
This review is about item#02490232.
Agricultural irrigation equipment
From Japan
On 2014-03-15 15:51:58
It was good to be able to exchange on their own the same as those being used in agricultural irrigation equipment.
This review is about item#02490232.
Ventilation fan control of greenhouses
From Japan
On 2013-12-19 18:06:12
Use mode, it is useful to be a wide range of settings, such as time.
This review is about item#02490232.
Used to shift the timing of use of equipment
From Japan
On 2013-11-21 08:01:10
Way of giving input, but on-delay timer of how to set I was able to immediately understand, because the description of how to take the output was unkind, too good to are explained a little more easy to understand.
This review is about item#02490232.
Plastic molding machine
From Japan
On 2013-08-22 10:50:56
Since the same thing that was used until now, the Toka durability, do not know and do not try to use a little more.
This review is about item#02490266.
Operation power supply circuit
From Japan
On 2012-09-04 17:01:54
It was adopted in the change of the circuit. Previously there is also used track record of the same model, there is no particular problem.
This review is about item#02490232.