NoteBuy more than* S$150* and get FREE SHIPPING

  • Solid-State Timer H3Y-2, DC Power Source

Solid-State Timer H3Y-2, DC Power Source H3Y-2 DC12 10S

5.00 (4)
H3Y-2 DC12 10S
Package Qty.
Ship pack of
45.43 SGD
In stock
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Operating Temperature Range (deg C)
Power Supply Voltage (V)
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
Below 21.5 below x63x28
Opreration Method
Operations with time limit
Maximum Time Scale
Terminal Shape
Plug-in (surface mounting) 8-pin
Reset Method
Self recovery
Noise Immunity
Square wave noise simulator (pulse width of 100 ns/1micros rise 1ns)+/-1.5 kV
Set Error
less than +/-10%+/-50ms (during full-scale)
Impact Resistance (Malfunction)
100 m/s2 6 directions, 3 times each
Vibration Resistance (malfunction)
10 to 55Hz, single amplitude 0.5mm, 3 directions, 3 times each
Withstand Voltage
Between conductive terminals and exposed non-charged metal parts (excluding terminal screws): AC2000V 50/60Hz 1min Between operation power supply circuit and system control output: AC2000V 50/60Hz 1min Between unlike pole contacts: AC2000V 50/60Hz 1min Between non-continuous points of contact: AC1000V 50/60Hz 1min
Impulse Voltage(V)
Power terminal spacing: 1k Between conductive terminal and exposed non-charging metal spacing: 1.5k
Operating Time Variation
less than +/-1% (during full-scale)
Insulation Resistance (Mohm)
100 or more (measured with DC500V mega)
Control Output
AC250V 5A resistance load (cosphi=1) Minimum applied load DC5V 1mA (P standard and reference values)
Effect of Temperature
less than +/-2% (during full-scale)
Electrical Service Life (rated load)
More than 500,000 times (AC250V 5A resistance load switching frequency 1800 times/h) (at room temperature)
Time Limit Contact
Operating Mode
Power-on delay
Ambient Humidity
35 - 85%
Electrostatic Yield Strength
4 kV (malfunction), 8 kV (breakage)
Time Specification
0.5s - 10s
Release Voltage
10 or more% of the supply voltage
Weight (g)
About 50
Recovery Time
0.1s or less (including in-process reset)
Power Consumption
Before time-up : about 0.1W After time-up : about 1.1W (at DC12V)
Allowable Voltage Range(V)
90 to 110% of power supply voltage For continuous use at 50degreeC, use at 95 to 110% of the supply voltage
Impact Resistance
1000 m/s2 6 directions, 3 times each
Vibration Resistance
10 to 55Hz, single amplitude 0.75mm, 3 directions, 1h each
Voltage Influence
less than +/-2% (during full-scale)
Operating Ambient Temperature (deg C)
-10 to +50 (however, no freezing)
Protection Structure
-10 to +55 (however, no freezing)
Electrical Life
10 or more,000,000 times (no load, opening/closing frequency 1800 times per hour)
Storage Temperature (DegreeC)
-25 to 65 (however, no freezing)
Customer Reviews
5 star 4
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
4 Customer Reviews
The reviews are automatic translation.
LED stop lamp blinks timer setting time, was to then switch to light up
From Japan
On 2016-05-04 20:17:19
Amount of money, are satisfied with the quality. Profession because "maintenance of equipment." Omron products are accustomed to handle, easy to use.
This review is about item#02089236.
Timer of the work machine of the pump
From Japan
On 2015-06-29 19:16:57
Compact may be. Set easy to be, it will be saved.
This review is about item#02089202.
Sequence change of power equipment
From Japan
On 2013-12-22 18:04:35
Mmm ... Was the Omron product normally! Of course, the operation down pat! !
This review is about item#02089324.
12 volt use in battery power supply control
From Japan
On 2013-11-06 22:42:26
We are satisfied about the product, but because it does not come with detailed instructions, have been struggling to mounting. I want you to put even manual is the next time you buy.
This review is about item#39073553.