Buy more than* S$200* and get FREE SHIPPING

  • Solid-State Timer H3Y-2, DC Power Source

Solid-State Timer H3Y-2, DC Power Source H3Y-2 DC12 10S

5.00 (4)
Item.#
02089193
Mfr.#
H3Y-2 DC12 10S
Package Qty.
1PC
Ship pack of
1
45.43 SGD
ADD TO CART
Shipped after 2017-05-29
Now we ship to...
...see all
Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Electrostatic Yield Strength
4 kV (malfunction), 8 kV (breakage)
Time Specification
0.5s - 10s
Release Voltage
10 or more% of the supply voltage
Reset Method
Self recovery
Power Supply Voltage (V)
DC12
Operating Mode
Power-on delay
Weight (g)
About 50
Impact Resistance (Malfunction)
100 m/s2 6 directions, 3 times each
Vibration Resistance (malfunction)
10 to 55Hz, single amplitude 0.5mm, 3 directions, 3 times each
Withstand Voltage
Between conductive terminals and exposed non-charged metal parts (excluding terminal screws): AC2000V 50/60Hz 1min Between operation power supply circuit and system control output: AC2000V 50/60Hz 1min Between unlike pole contacts: AC2000V 50/60Hz 1min Between non-continuous points of contact: AC1000V 50/60Hz 1min
Impulse Voltage(V)
Power terminal spacing: 1k Between conductive terminal and exposed non-charging metal spacing: 1.5k
Operating Time Variation
less than +/-1% (during full-scale)
Insulation Resistance (Mohm)
100 or more (measured with DC500V mega)
Protection Structure
-10 to +55 (however, no freezing)
Effect of Temperature
less than +/-2% (during full-scale)
Electrical Service Life (rated load)
More than 500,000 times (AC250V 5A resistance load switching frequency 1800 times/h) (at room temperature)
Recovery Time
0.1s or less (including in-process reset)
Power Consumption
Before time-up : about 0.1W After time-up : about 1.1W (at DC12V)
Opreration Method
Operations with time limit
Maximum Time Scale
10s
Time Limit Contact
2c
Terminal Shape
Plug-in (surface mounting) 8-pin
Operating Temperature Range (deg C)
IP40
Form
H3Y-2
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
Below 21.5 below x63x28
Ambient Humidity
35 - 85%
Allowable Voltage Range(V)
90 to 110% of power supply voltage For continuous use at 50degreeC, use at 95 to 110% of the supply voltage
Impact Resistance
1000 m/s2 6 directions, 3 times each
Vibration Resistance
10 to 55Hz, single amplitude 0.75mm, 3 directions, 1h each
Voltage Influence
less than +/-2% (during full-scale)
Operating Ambient Temperature (deg C)
-10 to +50 (however, no freezing)
Control Output
AC250V 5A resistance load (cosphi=1) Minimum applied load DC5V 1mA (P standard and reference values)
Electrical Life
10 or more,000,000 times (no load, opening/closing frequency 1800 times per hour)
Storage Temperature (DegreeC)
-25 to 65 (however, no freezing)
Noise Immunity
Square wave noise simulator (pulse width of 100 ns/1micros rise 1ns)+/-1.5 kV
Set Error
less than +/-10%+/-50ms (during full-scale)
Customer Reviews
5 star 4
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
4 Customer Reviews
The reviews are automatic translation.
LED stop lamp blinks timer setting time, was to then switch to light up
5
From Japan
On 2016-05-04 20:17:19
Amount of money, are satisfied with the quality. Profession because "maintenance of equipment." Omron products are accustomed to handle, easy to use.
This review is about item#02089236.
Timer of the work machine of the pump
5
From Japan
On 2015-06-29 19:16:57
Compact may be. Set easy to be, it will be saved.
This review is about item#02089202.
Sequence change of power equipment
5
From Japan
On 2013-12-22 18:04:35
Mmm ... Was the Omron product normally! Of course, the operation down pat! !
This review is about item#02089324.
12 volt use in battery power supply control
5
From Japan
On 2013-11-06 22:42:26
We are satisfied about the product, but because it does not come with detailed instructions, have been struggling to mounting. I want you to put even manual is the next time you buy.
This review is about item#39073553.