Item Feature
Minimum Signal Input Time (sec)
Output Type
Relay 2c (time limit)
Insulation Resistance (Mohm)
More than 100 (with DC500V mega)
Time Specification
0.05s - 300h
Recovery Time
0.1 s or below
Power Supply Voltage (V)
AC100 - 240(50/60Hz)/DC100-125
Ambient Humidity
35 - 85%
Weight (g)
About 90
Setting Time
Major figures: (hours) 1.2:(sec)0.05 - 1.2, (min, hrs) 0.12-1.2,(10h)1.2-12 3:(sec, min hrs)0.3-3, (10h)3-30 12:(sec, min, hrs)1.2-12, (10h)12-120 30: (Hrs, min, sec) 3-30, (10 h) 30-300
Noise Immunity
Square wave noise simulator (pulse width of 100 ns/1 micro s rise 1 ns) +/- 1.5 kV, however, no voltage between the input terminals is +/- 600 V
Set Error
+/-5% (rate over a full scale) of +/-50 ms or less
Impact Resistance (Malfunction)
100 m/s2 6 direction 3 times each
Vibration Resistance (malfunction)
10 To 55Hz cantilever amplitude of 0.5mm 3-direction each 10min
Contact output type 4 operation multi
Vibration Resistance
10 To 55 Hz single amplitude 0.75 mm each 2 h three-way
Operating Time Variation
+/-0.2% or less (Percentage of the maximum scale value) (the 1.2 s 3 s range is +/- 0.2% +/- 10 ms or less)
Release Voltage
Less than 10% of the supply voltage
Power Consumption
WHEN THE RELAY IS ON / About 2VA(1.6W) RELAY OFF TIME / About. 1.3VA(1.1W) At AC240V 60Hz
This product is manufactured in Japanese standards. Please check the specification before you order., Please do not use the inverter output as a power source. Caution advised against non-contact output by sensors as that will cause timer to turn on or off possible rush currents, as result in possible rush currents.
Effect of Temperature
+/-1% or less (Percentage of the maximum scale value) (the 1.2 s 3 s range is +/- 1% +/- 10 ms or less)
Time Base Range
4- stage switchable type SEC (seconds), min (minute), hrs (hours) x 10 h (hours) selection
Input Method
Pin Type
Maximum Time Scale
Protection Structure
IP40 (panel surface)
Operating Temperature Range (deg C)
-10 to +55 (however, no freezing)
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
Electrostatic Yield Strength
Malfunction: 8kav, breakdown: 15 kV
Operating Mode
Scale Type
4- stage switchable type Select 1.2, 3, 12, or 30
Control Output
AC250V/DC30 5A DC 125 V 0.15 A Resistance load (cosphi=1) Minimum applied load DC5V10mA (P levels and reference values)
Storage Temperature Range (degree c)
-25 To + 65 (with no freezing)
Impact Resistance
1000 m/s2 6 way 3 times each
Impulse Voltage(V)
Power terminal spacing: 3k Conductive terminal and exposed non-charging metal spacing: 4.5k
Voltage Influence
+/-0.2% or less (Percentage of the maximum scale value) (the 1.2 s 3 s range is +/- 0.2% +/- 10 ms or less)
Mechanical: 20 million times (no load, opening and closing frequency 1800 times/h) Electrical: More than 100000 (AC250V5A resistance load switching frequency 1800 times/h)
Power Reset
Minimum power supply open time 0.1 s
Withstand Voltage
Live metal parts / non-charging from the metal :AC2000V50/60 Hz 5 min Operation circuit between :AC2000V50/60 Hz 5 min with control outputs Point of contact between unlike poles: AC2000V 50/60Hz 1min Point of contact between discontinuity:AC1000V 50/60Hz
Allowable Voltage Range
85 to 110% of power supply voltage
Customer Reviews
5 star 9
4 star 2
3 star 3
2 star 0
1 star 0
Review Rating: 4.43
14 Customer Reviews
The reviews are automatic translation.
Adding to the control panel
From Japan
On 2015-08-21 10:51:26
Mounting behavior was both good.
This review is about item#02490232.
Timer for industrial machinery
From Japan
On 2015-05-29 09:45:08
There is no particular trouble for the goods. Replacement in Discontinued products survive found. In addition, very survive even arrive the next day.
This review is about item#02490266.
Use the time limit of the drainage.
From Japan
On 2014-10-22 13:21:27
It went very well.
This review is about item#02490232.
From Japan
On 2014-10-10 16:14:05
Old goods and compatible There could be replaced soon
This review is about item#02490266.
B2 mode, intermittent air blow use
From Japan
On 2014-05-21 09:49:06
Cheaper price than the twin timer. Other 1) is good it is instantaneous contact in the interval mode. 2) power supply, start, the use of the gate I want to various thinking.
This review is about item#02490232.
Agricultural irrigation equipment
From Japan
On 2014-03-15 15:51:58
It was good to be able to exchange on their own the same as those being used in agricultural irrigation equipment.
This review is about item#02490232.
Ventilation fan control of greenhouses
From Japan
On 2013-12-19 18:06:12
Use mode, it is useful to be a wide range of settings, such as time.
This review is about item#02490232.
Used to shift the timing of use of equipment
From Japan
On 2013-11-21 08:01:10
Way of giving input, but on-delay timer of how to set I was able to immediately understand, because the description of how to take the output was unkind, too good to are explained a little more easy to understand.
This review is about item#02490232.
Plastic molding machine
From Japan
On 2013-08-22 10:50:56
Since the same thing that was used until now, the Toka durability, do not know and do not try to use a little more.
This review is about item#02490266.
Operation power supply circuit
From Japan
On 2012-09-04 17:01:54
It was adopted in the change of the circuit. Previously there is also used track record of the same model, there is no particular problem.
This review is about item#02490232.