Solid-State Timer H3Y-2, Ac Power Source H3Y-2 AC200-230 1S
(17)
- Item.#
- 02490345
- Mfr.#
- H3Y-2 AC200-230 1S
- Package Qty.
- 1PC
- Ship pack of
- 1
Item Feature
- Caution
- This product is manufactured in Japanese standards. Please check the specification before you order.
- Specification
- Fixed time range
- Operating Ambient Temperature (deg C)
- -10 to 50 (however, no freezing)
- Insulation Resistance (Mohm)
- 100 or more (for DC500V meggers)
- Protection Structure
- IP40
- Form
- H3Y-2
- Power Supply Voltage (V)
- AC200 - 230
- External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
- Below 21.5 x 63 x below 28
- Opreration Method
- Operations with time limit
- Voltage Influence
- less than +/-2% (at full-scale)
- Number of Pins
- 8
- Lifespan
- Mechanical: more than 10,000,000 times (no load, switching frequency of 1800 times/h)
Electrical: more than 500,000 times (AC250V, 3A resistance load, switching frequency 1800 times/h) at room temperature
- Compatible Safety Standards
- UL508, CSA C22.2No.14, LR acquired, EN61812-1, IEC60664-1 2.5 kV / 2
- Terminal Shape
- Plug-in (surface attachment)
- Control Output
- AC250V 5A resistance load (cosphi =1), smallest application load: DC5V 1mA (P level, reference value)
- EMC Standard
- EMI: EN61812-1 Radiated interference field strength: EN55011 Group1 class A Noise Terminal voltage: EN55011 Group1 class A EMS: EN61812-1 Electrostatic discharge immunity: IEC61000-4-2 8kV air Electric field strength immunity (AM modulation): IEC61000-4-3 10 V/m (80MHz-1 GHz) Burst noise immunity: IEC61000-4-4 2kV power and output lines Surge immunity: IEC61000-4-5 2k between land 1kV between lines
- Vibration Resistance (malfunction)
- 10 to 55Hz, single amplitude 0.5mm, 3 directions, 10 min each
- Impact Resistance
- 1000 m/s2 6 directions, 3 times each
- Impulse Voltage(V)
- Between power terminals : 3k
Between conductive part terminal and an exposed non-charged metal section: 4.5k
- Withstand Voltage
- AC2000V 50/60Hz 1 min
Between conductive part terminals and non charged exposed metal parts (excluding the terminal screw)
Between operation power circuit and control output
Contact between different poles
AC1000V 50/60Hz 1min
Between non-continuous contacts
- Reset Method
- Self-reset
- Time Specification
- 0.1s - 1.0s
- Time Limit Contact
- 2c
- Operating Mode
- Power-on delay
- Storage Temperature (DegreeC)
- -25 to 65 (however, no freezing)
- Ambient Humidity
- 35 - 85%
- Weight (g)
- About 50
- Electrostatic Yield Strength
- 4kV (malfunction), 8kV (breakdown)
- Operating Time Variation
- less than +/-1% (at full-scale)
- Release Voltage
- 10 or more% of the supply voltage
- Maximum Time Scale
- 1s
- Effect of Temperature
- Less than +/-2% (Percentage of maximum scale value)
- Noise Immunity
- Square wave noise simulator (pulse width of 100 ns/1micros rise 1 ns)+/-1.5 kV
- Recovery Time
- 0.1s or less (including in-process reset)
- Set Error
- less than +/-10%+/-50ms (at full-scale)
- Impact Resistance (Malfunction)
- 100 m/s2 6 directions, 3 times each
- Allowable Voltage Range(V)
- 85 to 110% of power supply voltage
Continuous use at 50degreeC temperature range uses 90 to 110% of the supply voltage
- Power Consumption
- At AC230V 60Hz
When relay is OFF: about 1.5VA/1.1W
When relay is ON: about 2.2VA/1.8W
- Vibration Resistance
- 10 to 55Hz, single amplitude 0.75mm, 3 directions, 1h each
|