NoteBuy more than* S$150* and get FREE SHIPPING

  • General-Purpose Relay LY2

General-Purpose Relay LY2 LY2-0 DC24

4.58 (19)
LY2-0 DC24
Package Qty.
Ship pack of
14.87 SGD
Shipped after 2016-10-24
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Maximum Switching Frequency (times/hour)/mechanical
Number of Pins
Number of Poles
Coil Resistance (ohm)
Power Consumption (VA, W)
About 0.9
Rated Current (mA)
Rated Voltage (V)
Installation Shape
Standard form
Weight (g)
About 40
Maximum Contact Voltage (V)
Release Voltage
More than 10%
Coil Inductance (H)/ Iron Working Time
Reference value: 5.72
Coil Inductance (H)/ Iron Opening Time
Reference value: 3.20
Operating Time
25ms or less
Withstand Voltage
Between coil and contacts: AC2000V 50 / 60Hz 1min poles between contacts: AC2000V 50 / 60Hz 1min same polarity between contacts: AC1000V 50 / 60Hz 1min
Electrical Durability
More than 500,000 times (rated load switching frequency of 1800 times / h)
Mechanical Durability
More than 100 million times (switching frequency of 18000 times / h)
Insulation Resistance (Mohm)
More than 100
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
21.5 The following x 40.5 x 28.0 below below
Recovery Time
25ms or less
Maximum Switching Frequency (times/hour)/rated load
Operating Voltage
80% or less
Rated Current
Protection Structure
Closed (with case)
Impact Resistance
Terminal Shape
PCB terminals
Indicator Lamp
Contact Materials
Ag alloy
Contact Type
Inductive Load (cos phi =0.4, L/R = 7 ms)
DC24V 5A
Resistance Load
DC24V 10A
Impact Resistance (Malfunction)
Failure Rate P Level (Reference Value: Opening/Closing Frequency 120 times/min)
DC5V 100mA
Maximum Voltage (V)
CR Circuit
Ambient Humidity
5 ~ 85% RH
Compatible Standard
(UL) standard number: UL508 File No.: E41643 (CSA) standard number: C22.2 No.0, No.14 file No.: LR31928 (TUV) R50030064 (SEV) 98.5 50071.02 (other) Compliance: Electrical Appliance Safety Act compliant goods
Vibration Resistance
10 ~ 55 ~ 10Hz piece amplitude 0.5mm (double amplitude 1.0mm)
Contact Resistance (mohm)
50 or less
Operating Ambient Temperature (deg C)
-25 To 55 (with no icing or condensation) if the following energizing current 4A, -25 ~ 70 degree C
Vibration Resistance (malfunction)
10 ~ 55 ~ 10Hz piece amplitude 0.5mm (double amplitude 1.0mm)
Reference form
Contact Maximum Value
Resistive load / 10A inductive load / 10A
Customer Reviews
5 star 14
4 star 2
3 star 3
2 star 0
1 star 0
Review Rating: 4.58
19 Customer Reviews
The reviews are automatic translation.
Used for the exchange of the antenna switching parts of 500W auto tuner
From Japan
On 2016-09-01 09:08:19
Exchange did to our relay was the deterioration of the IC-AT500. Satisfaction to have become the intrinsic properties after the exchange.
This review is about item#2492192.
Mechanical repair
From Japan
On 2016-03-17 22:36:46
Without LED, the price is also cheap it was good
This review is about item#02492113.
Relay exchange of foundation of the operating device
From Japan
On 2015-12-22 10:07:50
Since well before the operation machine, companies that sell repair, but was in trouble because he was going out of business was saved if there is the same product.
This review is about item#02492226.
When the hobby of woodworking, for use in wireless SW equipment manufacture of dust collector (production end).
From Japan
On 2015-11-17 16:47:10
Nothing is no problem about the product. At the time of order, or not there needs to be carefully view the socket fit a relay, it will not be able to use the wrong.
This review is about item#02492086.
Used as a replacement part for the control of the machine
From Japan
On 2015-10-30 22:17:55
It is good in a replacement.
This review is about item#02492113.
Solar of ON / OFF for automotive
From Japan
On 2015-10-30 18:38:27
It was used in solar charging of ON / OFF of the sub-battery for the vehicle. Solar control and from the solar panel has been provided in the middle of the wiring to the BT. When traveling charger is working, you do not would Ne turn off the power from the solar. Using the ACC power, solar power to OFF, ACC is the made to OFF, so that the solar turns ON, was. Also for other Omron 100V, when the work is external charging system, automatically also like made to OFF, it is. Properly, and not the wiring, because you broke the BT (experienced) ...
This review is about item#02492104.
Exchange for failure
From Japan
On 2015-09-17 08:49:06
Domestic sounds good.
This review is about item#02492244.
For independent photovoltaic power generation equipment
From Japan
On 2015-07-31 15:25:54
Operating time is a little long in the 20ms but satisfied
This review is about item#02492113.
Use to automate car
From Japan
On 2015-04-04 18:51:27
No problem to a feeling of use, only without the perfect that it is a little more low-cost
This review is about item#02492104.
Repair of water heater
From Japan
On 2014-10-25 11:00:20
Relay exchange of that operated outside in 20 years. It is durable.
This review is about item#02492174.