  • General-Purpose Relay MY4
  • General-Purpose Relay MY4
  • General-Purpose Relay MY4

General-Purpose Relay MY4 MY4N DC100/110

4.32 (25)
Item.#
02493075
Mfr.#
MY4N DC100/110
Package Qty.
1PC
Ship pack of
1
19.61 SGD
ADD TO CART
In stock
Now we ship to...
...see all
Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Coil Inductance (H)/ Iron Opening Time
Reference values: 45.60 (60Hz)
Contact Maximum Value
3A
Indicator Lamp
Yes
Impact Resistance
1000m/s2
Contact Materials
Au clad + Ag alloy
Terminal Shape
Plug-in termination
Maximum Contact Voltage (V)
AC250, DC125
Number of Pins
14
Rated Voltage (V)
DC100/110
Maximum Switching Frequency (times/hour)/rated load
1800
Protection Structure
Closed (with case)
Number of Poles
4
Maximum Voltage (V)
110% of the rated voltage
Release Voltage
More than 10%
Coil Inductance (H)/ Iron Working Time
Reference values: 86.20 (60Hz)
Insulation Resistance (Mohm)
100 or more (at DC500V insulation resistance meter to measure the same place as the withstand voltage)
Recovery Time
20ms when below the rated operating voltage applied.Ambient temperature conditions 23 degree C
Operating Time
20ms when below the rated operating voltage applied.Ambient temperature conditions 23 degree C
Rated Current (mA)
8.7 / 9.6 (when coil temperature of 23 degrees, tolerance DC coil resistance +/- 15%)
Vibration Resistance
10 ~ 55 ~ 10Hz piece amplitude 0.5mm (double amplitude 1.0mm)
Maximum switch Current
AC: 3A (resistive load (cos phi = 1)), 3A (inductive load (cos phi = 0.4)) DC: 3A (resistance load), 3A (inductive load (L / R = 7ms))
Maximum Switching Capacity
AC: 660VA (resistive load (cos phi = 1)) AC: 176VA (inductive load (cos phi = 0.4))
Compatible Standard
(CSA) standard number: C22.2 No.0, No.14 file No .: LR31928 (LR) 98/10014 (UL) standard number: UL508 file No .: E41515 (VDE) 112467UG (other) Compliance: Electric Appliance and Material Safety Law compliant goods
Power Consumption (VA, W)
About 0.9
Rated Current (A)
3
Ambient Humidity
5 ~ 85% RH
CR Circuit
Nothing
Inductive Load (cos phi =0.4, L/R = 7 ms)
AC220V 0.8A, DC24V 1.5A
Resistance Load
AC220V 3A, DC24V 3A
Diode
Nothing
Contact Arrangement
4c
Failure Rate P Level (Reference Value: Opening/Closing Frequency 120 times/min)
DC1V 1mA
Impact Resistance (Malfunction)
200m/s2
Installation Shape
Standard form
Maximum Switching Frequency (times/hour)/mechanical
18000
Operating Voltage
80% or less
Weight (g)
About 35
Contact Mechanism
Single
Operating Ambient Temperature (deg C)
-55 To 70 (freezing, without condensation)
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
21.5 The following x 28 x 36 or less below
Classification
Operation indicator Built-in
Coil Resistance (ohm)
Reference: 11440 (when coil temperature of 23 degrees, tolerance DC coil resistance +/- 15%)
Withstand Voltage
Between coil and contacts, between the poles contact: AC2000V 50 / 60Hz 1min same polarity between contacts: AC1000V 50 / 60Hz 1min
Electrical Durability
200 000 times or more (rated load, switching frequency 1800 times / h, ambient temperature conditions + 23 degree C )
Mechanical Durability
More than 100 million times (switching frequency 18000 times / h)
Contact Resistance (mohm)
50 or less (by DC5V 1A voltage drop method)
Vibration Resistance (malfunction)
10 ~ 55 ~ 10Hz piece amplitude 0.5mm (double amplitude 1.0mm)
Customer Reviews
5 star 18
4 star 0
3 star 5
2 star 1
1 star 1
Review Rating: 4.32
25 Customer Reviews
The reviews are automatic translation.
Power amplifier repair of
3
From Japan
On 2016-08-16 21:18:28
It was used without any problem as a compatible product of NRL-4P3ADC12-04
This review is about item#2493014.
Training kit to be used in the training
5
From Japan
On 2016-07-15 16:34:14
Since Omron has been used without any problems.
This review is about item#02493093.
Used to control circuit of AC100V]
5
From Japan
On 2016-06-23 17:51:43
With stable quality, it can be used with confidence.
This review is about item#02493041.
Replacing parts of the indoor pump
5
From Japan
On 2016-06-18 10:37:34
To order in the evening on Thursday I received the goods in the morning on Saturday. I was saved because it was instant delivery.
This review is about item#02492953.
Maintenance of machinery
3
From Japan
On 2016-06-13 16:34:31
I a genuine product that is attached to the machine, but buy for the preliminary order to break in one to two years.
This review is about item#02493057.
For control
3
From Japan
On 2016-03-14 19:36:08
Commercial products and we can use without inferiority. It is good to arrive is early is.
This review is about item#02493102.
Machine repair in DIY
5
From Japan
On 2016-03-10 15:07:23
Was saved will receive the goods on Sunday of ordering even though the next day on Saturday. Monotarou san is very reliable.
This review is about item#02492953.
Used to control the equipment
5
From Japan
On 2015-12-08 08:53:04
When the relay is in malfunction, the mount so you exchange, is very convenient because it can be easily replaced if damaged.
This review is about item#02493057.
Exchange for failure
5
From Japan
On 2015-09-17 08:42:50
Domestic production is good.
This review is about item#02493057.
Replacement of the control panel in the electrical parts for water pumps
5
From Japan
On 2014-09-30 16:49:46
Omron products, for you are able to ship the order on Saturday, is grateful. Company dealing with Omron products on Saturday, most Sundays off. Monday it is possible to work, I was able to successfully complete. I was saved.
This review is about item#02493057.