Buy more than* S$200* and get FREE SHIPPING

  • General-Purpose Relay MY4

General-Purpose Relay MY4 MY4N-D2 DC100/110

4.48 (33)
MY4N-D2 DC100/110
Package Qty.
Ship pack of
22.99 SGD
Shipped after 2018-03-26
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Terminal Shape
Plug-in termination
Maximum Contact Voltage (V)
Rated Voltage (V)
Impact Resistance (Malfunction)
Maximum Switching Frequency (times/hour)/rated load
Number of Poles
Operating Voltage
80% or less
Maximum Voltage (V)
110% of the rated voltage
Contact Mechanism
Power Consumption (VA, W)
From about 0.9 to about 1.1 (60Hz)
Contact Maximum Value
Ambient Humidity
5 to 85%RH
Indicator Lamp
Inductive Load (cos phi =0.4, L/R = 7 ms)
AC220V 0.8A,DC24V 1.5A
Withstand Voltage
Between coil and contacts, contacts between different poles: AC2000V 50 / 60Hz 1min same polarity between contacts: AC1000V 50 / 60Hz 1min
Electrical Durability
50 000 times or more (Rated load, switching frequency 1800 times/h, ambient temperature conditions+23 degree C)
Mechanical Durability
(18000 times / h switching frequency) 100 000 000 or more times
Compatible Standard
(CSA) standard number: C22.2 No.0, No.14 file No .: LR31928 (LR) 98/10014 (UL) standard number: UL508 File No .: E41515 (VDE) 112467UG
Vibration Resistance (malfunction)
10 to 55 to 10Hz single amplitude 0.5mm (double amplitude 1.0mm)
Insulation Resistance (Mohm)
(At DC500V insulation resistance tester and measure the same place as the withstand voltage) more than 100
Diode operation display light Built-in
Coil Resistance (ohm)
Reference: 11440 (23 degrees when the coil temperature, DC coil resistance tolerance +/- 15%)
Contact Materials
Au + Ag alloy clad
Resistance Load
AC220V 3A,DC24V 3A
Contact Arrangement
Number of Pins
Failure Rate P Level (Reference Value: Opening/Closing Frequency 120 times/min)
DC1V 1mA
Installation Shape
Standard form
Protection Structure
Closed (Case)
Maximum Switching Frequency (times/hour)/mechanical
Weight (g)
Release Voltage
More than 10%
Coil Inductance (H)/ Iron Working Time
Reference value: 86.20 (60Hz)
Coil Inductance (H)/ Iron Opening Time
Reference value: 45.60 (60Hz)
Rated Current (A)
CR Circuit
Impact Resistance
Rated Current (mA)
8.7 / 9.6 (23 degrees when the coil temperature, DC coil resistance tolerance +/- 15%)
Vibration Resistance
10 to 55 to 10Hz single amplitude 0.5mm (double amplitude 1.0mm)
Maximum switch Current
(Resistive load (cosphi = 1)) (inductive load (cosphi = 0.4)) DC 3A, 3A:: AC 3A (resistive load), 3A (inductive load (L / R = 7ms))
Maximum Switching Capacity
(Resistive load (cosphi = 1)) 660VA AC:: AC 176VA (inductive load (cosphi = 0.4))
Contact Resistance (mohm)
50 or less (with DC5V 1A voltage drop method)
Operating Ambient Temperature (deg C)
-55 to 70(No freezing No condensation)
Recovery Time
Less than 20ms rated operating voltage is applied. Ambient temperature conditions 23 deg C
Operating Time
Less than 20ms rated operating voltage is applied. Ambient temperature conditions 23 deg C
Customer Reviews
5 star 26
4 star 0
3 star 5
2 star 1
1 star 1
Review Rating: 4.48
33 Customer Reviews
The reviews are automatic translation.
Tape deck repair
From Japan
On 2018-03-20 17:29:03
Since it is a reliable manufacturer's part, I am using it with confidence.
This review is about item#39088646.
Maintenance change
From Japan
On 2018-02-21 15:06:27
It is made by a Japanese manufacturer, so you can trust it very well.
This review is about item#2493041.
During repair and maintenance of equipment
From Japan
On 2018-02-09 17:13:41
We use safe and secure with manufacturer products. I am satisfied with the price as well.
This review is about item#2492953.
Used for switching power supply (inverter output) from solar panel and household power supply
From Japan
On 2017-12-21 13:44:37
Since the control panel of the company that I worked in before was using OMRON products and it was a very reliable part, this time I installed a solar panel on power saving at home and is using it for switching AC power. Switching instantly without cutting, I am very satisfied.
This review is about item#2492987.
For replacing Chinese made relay
From Japan
On 2017-11-23 15:50:12
Because the relay made in China is extremely short in life expectancy, it is not usable unless it is made in Japan.
This review is about item#2493084.
Used for control circuit
From Japan
On 2017-08-20 17:39:12
I could not get it on consecutive holidays, but it was saved because the delivery date was early.
This review is about item#2493041.
Used for opening and closing the motor
From Japan
On 2017-05-28 19:28:39
Since it is made by a trusted manufacturer, I used it with confidence, but it works without problems.
This review is about item#2492996.
Parts in the control panel
From Japan
On 2016-12-21 14:46:19
As always you have to keep it all the time so you can ask immediately. I am sorry for placing orders little by little without resorting to large amounts. Product has no problem
This review is about item#2492953.
Repair of power amplifier
From Japan
On 2016-08-16 21:18:28
It was possible to use it as a compatible product of NRL - 4P3ADC12 - 04 without problems
This review is about item#2493014.
Practice kit for training
From Japan
On 2016-07-15 16:34:14
Because it is made by OMRON, it can be used without any problem.
This review is about item#02493093.