NoteBuy more than* S$150* and get FREE SHIPPING

  • Floatless Level Switch, Basic Type, 61 F-G
  • Floatless Level Switch, Basic Type, 61 F-G
  • Floatless Level Switch, Basic Type, 61 F-G

Floatless Level Switch, Basic Type, 61 F-G 61F-G1 AC100/200

5.00 (1)
61F-G1 AC100/200
Package Qty.
Ship pack of
149.90 SGD
In stock
Now we ship to...
...see all
Item Feature
Electrical Service Life (rated load)
500000 times or more
Working Condition
Water purification in general, sewage
Reset Resistance between Electrodes (ohm)(Recommended Value)
About 15k to infinity
Withstand Voltage
AC2000V 50/60Hz 1min
Rated Voltage (V)
Controlled Object, Using Condition
Water purification in general, sewage
Tolerable Voltage Fluctuation
85-110% of the rated voltage
Ambient Humidity
5 to 85%RH
Compatible Cable
Less than 1km
Power Consumption (VA)
5.5 or less
AC220V 5A (resistive load), AC220V 2A (inductive load cosphi = 0.4)
Operating Ambient Temperature (deg C)
-10 to +55
Insulation Resistance (Mohm)
More than 100 (at DC500V mega)
Dynamic Resistance between Electrodes (ohm)(Recommended Value)
0 to About 4k
Current between Electrodes
About 1mA or less AC
Voltage between Electrodes
For general use
G1 type
Weight (g)
Electrical Life
15 million times or more
Automatic watering with idling prevention or drought alert function
This product is manufactured in Japanese standards. Please check the specification before you order., The length of the applicable cable is the value when using a 600V 0.75mm2 3 core cab tire cable which got fully isolated, that the stray capacitance of the line is larger when wire diameter get thicker (or core number gets larger) It will be shorter than
Customer Reviews
5 star 1
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
1 Customer Reviews
The reviews are automatic translation.
For drainage in the warehouse
From Japan
On 2015-08-01 21:01:16
Omron None of the float switch has been previously used but is a manufacturer that can be used with confidence. If fresh water is no problem with a stick-type electrode, but because this time to use for the drainage, were installed for use voltage 30V or less of the integrity of 100VAC and the float switch of the electromagnetic switch. Voltage between the electrodes is 8V.
This review is about item#38968912.