NoteBuy more than* S$150* and get FREE SHIPPING

  • Solid-State Timer H3CR-G
  • Solid-State Timer H3CR-G
  • Solid-State Timer H3CR-G

Solid-State Timer H3CR-G H3CR-G8L AC200-240

5.00 (3)
H3CR-G8L AC200-240
Package Qty.
Ship pack of
95.70 SGD
Shipped after 2016-10-24
Now we ship to...
...see all
Item Feature
Pin Type
Time Base Range
Only seconds
Protection Structure
IP40 (panel surface)
Operating Temperature Range (deg C)
-10-+55 (however, don't freeze)
Storage Temperature Range (degree c)
-25 to +65 (not in cases of freezing)
Weight (g)
Around 110
Ambient Humidity
35 - 85%
Star delta timer
Opreration Method
Limited-time operation
Tolerable Voltage Fluctuation
85 to 110% of power supply voltage
Maximum Time Scale
Installation Method
Embedded attachment / surface attachment
Time Specification
Scale figures 6:0.5-6s 12: 1-12s 60: 5-60s 120: 10-120s
Effect of Temperature
Below +/-1% (rate over maximum scale value)
Terminal Layout
Standard terminal arrangement
Scale Type
2 types, 4-stage switchable type Choose from 6, 12, 60, 120
EMC Standard
EMI: EN61812-1, radiated interference field strength: EN55011 Group1 class A, noise Terminal voltage: EN55011 Group1 class A, EMS: EN61812-1, electrostatic discharge immunity: IEC61000-4-2, field-strength immunity: IEC61000-4-3, conductive noise immunity: IEC61000-4-6, Burst noise immunity: IEC61000-4-4, surge immunity: IEC61000-4-5
Vibration Resistance (malfunction)
10 To 55Hz single amplitude of 0.5mm 3-direction each 10min
This product is manufactured in Japanese standards. Please check the specification before you order., Please do not use the inverter output as a power source. Caution advised against non-contact output by sensors as that will cause timer to turn on or off possible rush currents, as result in possible rush currents. Types H3CR-G8L-30/-G8EL-31 do no
Operating Time Variation
Below +/-0.2% (rate over maximum scale)
Compatible Safety Standards
UL508, CSA C22.2No.14, NK, LR acquired, EN61812-1, IEC60664-1 4kV/2 compatible
Withstand Voltage
AC2000V 50/60Hz 1min (between charging and non charging metal parts) AC2000V 50/60Hz 1min (between control and operation circuit) AC2000V 50/60Hz 1min (between differing pole contact points) AC2000V 50/60Hz 1min (between non continuous connection points)
Power Consumption (W)
Approx. 3.0 (12 VA) (AT AC240V)
Insulation Resistance (Mohm)
More than 100 (with DC500V mega)
Instantaneous Contact
Type H3CR-G8L
Power Supply Voltage (V)
AC200 - 240
Electrostatic Yield Strength
Malfunction: 8kV, breakdown: 15 kV
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
Allowable Voltage Range(V)
85 to 110% of power supply voltage
Release Voltage
10% or less of power supply voltage
Power Reset
Minimum power-source open time 0.5s
Reset Method
Self recovery
Switching Time
Total error +/- (25% (as a percentage of maximum height) + 5 ms) and below
Set Error
+/-5% (rate over maximum scale value) of +/-50 ms or less
Mechanical: over 20 million times (no load, open/close frequency of 1800 times/h) Electrical: More than 100 thousand times : (AC250V, 5A, resistance load, open/close frequency of 1800 times/h)
Noise Immunity
Square wave noise by noise simulator (pulse width of 100ns/1micros rise 1ns) +/-1.5kV (between power supply terminals)
Impact Resistance (Malfunction)
294m/s2 6 directions each 3 times
Control Output
Contact output: AC250V/DC30V 5A Resistance load (cosphi=1) Minimum applied load:DC5V 10mA (P levels and reference values)
Impulse Voltage(V)
Power terminal spacing: 3k Conductive terminal and exposed non-charging metal spacing: 4.5k
Output Type
Limit (relay): 1a (delta circuit), 1a(star circuit)
Impact Resistance
980m/s2 6 directions 3 times each
Vibration Resistance
10 To 55 Hz single amplitude 0.75 mm three-way each 2 h
Voltage Influence
Below +/-0.2% (rate over maximum scale)
Customer Reviews
5 star 3
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
3 Customer Reviews
The reviews are automatic translation.
For parts replacement
From Japan
On 2016-08-16 18:07:51
I went into the hand immediately. very convenient. We are satisfied.
This review is about item#8589147.
Control of water pumps
From Japan
On 2016-04-27 18:13:44
For star-delta type of have a timer with the control of water pumps broke one, there was need to urgently get. This product is another in the not found the middle people, was really helpful.
This review is about item#39072616.
Pumping pump control panel
From Japan
On 2015-01-31 11:24:22
no problem. It was the order of via electrical shop until now, it will be saved because it treats in Monotarou.
This review is about item#06862195.