Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Capacity (W)
15
Radiated Interference Field Intensity
EN61204-3 Class B compatibility
Weight (g)
180 or less
Output Indicator
Available (color: Green)
External Dimensions (Width (W)x Depth (D)x Height (H)) (mm)
35.1x98.5x89.9
Input Voltage (V)
AC100 - 240
Output Voltage Adjustable Range (%)
-20 to 20 (at V.ADJ)
Input Frequency (Hz)
50/60(47 - 63)
Power Factor
-
Ambient Humidity
30 to 85% (preservation of humidity 25 to 90%)
Type
Standard type
Disturbance Voltage
EN61204-3 Class B conformity, FCC class B compliance
Insulation Resistance (Mohm)
100 or more (batch output) and (batch input, contact patch[earts]/FG) at 2500V
Functions
Series operation: possible Parallel-operation: not possible Remote sensing function: not equipped
Under Voltage Detection Output
Not available
Output Holding Time
20 millisecond typ. (15 ms or more) (at rated normal power input
Output Current (A)
0.65
Safety Standards
UL:UL508(Listing), UL60950-1, UL1604(ClassI/Division2) cUL:CSA C22.2No.14, No.60950-1No.213(ClassI/Division2) EN:EN50178, EN60950-1
Frame
Covered type
Installation Method
DIN rail attachment type
Operating Ambient Temperature (deg C)
-10 - +70
Efficiency
80% or more
Storage Temperature (DegreeC)
-25 - +65
Output Ripple Noise Voltage
Below 1.0% (p-p)
Temperature Fluctuation
0.02%/deg C or less
Output Voltage (V)
24
Withstand Voltage
AC3.0kV 1min (input package) and between (output package)+(20 mA of detection current) AC2.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC500kV 1min between(batch input)and (batch output)(detection current of 100mA)
Over-Voltage Protection
Present (To automatically reset, turn off the power, wait for 3 minutes, then turn back on the power)
Starting Time (min)
1100 or less (at rated output)
Overcurrent Protection
At 105 to 106% of the rated inputcurrent, shaped drooping, intermittent operation, and automatic restarts occur
Input Curret (A)
At 100V input: 0.5 or less At 200V input: 0.25 or less
Vibration Resistance
Are normal each in 2 h of piece amplitude of 10-55 Hz 0.375 mm 3 directions.
Load Changes
0.8% or less (by a rated input, and at a 0 to 100% load)
Input Variation Influence
0.4% or less (with an input of AC85 - 264V at a 100% load)
Impact Resistance (m/s2)
150 (no abnormalities when all six directions were taken 3 times each)
Inrush Current (A)
When input is over 100V: over 17.4, when input is over 200V: over 35 (25deg C, for cold start)
Leakage Current (mA)
100V input time: 0.4 or below 200V input time: 0.75 or below
Customer Reviews
5 star 2
4 star 0
3 star 1
2 star 0
1 star 0
Review Rating: 4.33
3 Customer Reviews
The reviews are automatic translation.
Experiment
5
From Japan
On 2015-10-29 20:54:45
It is very satisfactory.
This review is about item#08530347.
Test display dexterity power of a fictional line
3
From Japan
On 2015-04-16 15:21:46
I was able to work with familiar because it uses the equivalent from the previous.
This review is about item#08530523.
Use attached to the control panel (power source such as a relay photoelectric sensor)
5
From Japan
On 2014-07-13 19:33:48
Location without taking, neat in chunks Ministry of space, very good.
This review is about item#08530602.