Buy more than* S$200* and get FREE SHIPPING

  • Power Relay G6B
  • Power Relay G6B
  • Power Relay G6B

Power Relay G6B G6B-1114P-US DC24V

5.00 (3)
Item.#
08588176
Mfr.#
G6B-1114P-US DC24V
Package Qty.
1PC
Ship pack of
1
6.68 SGD
ADD TO CART
In stock
Now we ship to...
...see all
Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Maximum Voltage (V)
160% (at 23 degree c)
Number of Poles
1-Pole
Weight (g)
About 3.5
Contact Resistance (mohm)
30 or less (DC5V voltage drop method0
Rated Current (A)
5
Insulation Resistance (Mohm)
1000 or more (DC500V)
Inductive Load (cos phi =0.4, L/R = 7 ms)
AC250V 2A, DC30V 2A
Terminal Shape
PCB terminal
Release Voltage
10 or more %
Maximum Contact Voltage (V)
AC380V DC125V
Protection Structure
Plastic seal form
Standard
UL, CSA certified standard goods
Coil Resistance (ohm)
2880+/-10% (Coil resistance value at +23 deg C)
Type
Single Stable form
Installation Method
Dedicated printed circuit board mounting
Contact Mechanism
Single (Ag alloy (Cd free material)
Operating Ambient Temperature (deg C)
-25 To + 70 (However no condensation and icing)
Withstand Voltage
Between coil and contacts : AC3000V 50/60HZ 1 min Between the homopolar contact points : AC 100V 50/60Hz 1 minute
Ambient Humidity
5 - 85%RH
Impact Resistance
1000m/s2
Maximun Contact Current (A)
5
Recovery Time (ms)
10 or less ( Actual value: about 1)
Coil Rated Voltage(V)
DC24
Impact Resistance (Malfunction)
100m/s2
Operating Time (ms)
10 or less (Actual value: about 3)
Operating Voltage
Less than 70 %
Resistance Load
AC250V 5A, DC30V 5A
Contact Arrangement
1a
Power Consumption (mW)
About 200
Failure Rate P Level (Reference Value: Opening/Closing Frequency 120 times/min)
DC5V 10mA
Purpose
Output use, etc of PC and control devices.
Vibration Resistance
10 to 55 to 10Hz half amplitude 0.75 mm (double amplitude 1.5 mm)
Rated Current (mA)
8.3+/-10% (Coil resistance value at +23 deg C)
Electrical Durability
100,000 times or more ( rated load switching frequency 1800 times/h)
Mechanical Durability
50 Million times or more (switching frequency 18,000 operations/h)
Vibration Resistance (malfunction)
10 to 55 to 10Hz half amplitude 0.75 mm (double amplitude 1.5 mm)
Customer Reviews
5 star 3
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
3 Customer Reviews
The reviews are automatic translation.
Repair of the foundation of the hot air blower
5
From Japan
On 2016-12-28 15:08:41
Not yet used. This should I as you were, but there is a place to be worried about the other one place.
This review is about item#8588194.
Machine control
5
From Japan
On 2016-06-13 11:51:41
Trading company you are using, so why dispatch of Omron product is slow, Omron products, but we have to buy in MonotaRo's.
This review is about item#39068407.
Power of control equipment
5
From Japan
On 2015-03-27 11:13:43
Small in size and have sufficient current capacity, it is what the price is also satisfactory. OMRON of peace of mind given the reliability.
This review is about item#08588151.