NoteBuy more than* S$150* and get FREE SHIPPING

  • Switching Power Supply S8VS
  • Switching Power Supply S8VS
  • Switching Power Supply S8VS

Switching Power Supply S8VS S8VS-01512

5.00 (2)
Package Qty.
Ship pack of
78.55 SGD
Shipped after 2016-10-31
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Mounting Direction
Standard attachment, sideways, on top
Storage Temperature (DegreeC)
-25 - +65
Input Frequency (Hz)
50/60Hz(47 - 450Hz)
Output Current (A)
Input Voltage (V)
AC100 - 240
Installation Method
Corresponds to DIN rail attachment
Power Factor
Temperature Fluctuation
0.05%/deg C or less
Terminal Block
Screw terminal block
Input Variation Influence
0.5% or less (input AC85 - 264V and 100% load)
Impact Resistance (m/s2)
150 (no abnormalities when all six directions were taken 3 times each)
Insulation Resistance (Mohm)
100 or more between (output package) and (BULK INPUT GROUND [EARTH]) at DC500V
Output Current Display
Not available
Series operation: not possible Parallel operation: not possible Low voltage detection display: Yes (color: red)
Inrush Current (A)
during 100V input: below 25A during 200V input: below 50A (d5 degrees, cold start)
Safety Standards
UL:UL508(Listing, Class2 Output:Per 1310), UL1604(Class[I]/Division2), UL60950-1 cUL:CSA C22.2 No.14(Class2 Output), No213(Class[I]/Division2) cUR:CSA C22.2 No.60950-1 EN/VDE:EN50178(=VDE0160)
Starting Time (min)
below 100 (at rated input/output power)
Ambient Humidity
25-85% (Saves between 25 and 90% humidity)
Alarm Output
Sink (emitter COM)
Vibration Resistance
Are normal each in 2 h of piece amplitude of 10-55 Hz 0.375 mm 3 directions.
Load Changes
1.5% or less (by a rated input and 0 to 100% load)
Withstand Voltage
AC3.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC2.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC1.0kV 1min between(batch input)and (batch output)(detection current of 20mA)
Output Voltage Adjustable Range (%)
-10-+15 (at V.AD)
Radiated Interference Field Intensity
EN61204-3 Class B compatibility
Outer Dimensions (Width W x Height H x Depth D) (mm)
higher Harmonics Current Regulation
EN61000-3-2 compatibility
74% or more
Output Indicator
Available(color: green)
Output Voltage (V)
Operating Ambient Temperature (deg C)
-10 - 60
Weight (g)
160 or less
Capacity (W)
Standard type
Peak Hold Current Display
Not available
Output Ripple Noise Voltage
Below 2.0% (p-p) (rated input and output)
Output Voltage Display
Not available
Leakage Current (mA)
During 100V input: less than .5 200V input: 1 or less
Over-Voltage Protection
(S) (Thinner diode clamping method) If the internal feeback circuit is damaged, the clamped voltage load may become damaged as well (approx. 140-190% of the rated output voltage).
Disturbance Voltage
EN61204-3 Class B conformity, FCC class A conformity
Overcurrent Protection
105 to 160% of the normal power output is in shaded shapes, automatic reset
Input Curret (A)
100 V input time: below 0.45 200V input time: below .25
Not available
Under Voltage Detection Output
Not available
Output Holding Time
20 ms or more (by rated input and output)
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
2 Customer Reviews
The reviews are automatic translation.
Training kit to be used in the training
From Japan
On 2016-07-15 16:34:59
Since Omron has been used without any problems. But it is a little high.
This review is about item#08591441.
Instrumentation of power supply
From Japan
On 2014-06-23 09:04:27
Easy-to-use compact
This review is about item#08591475.