Item Feature
Caution
This product is manufactured in Japanese standards. Please check the specification before you order.
Weight (g)
160 Or less
Capacity (W)
15
Mounting Direction
Standard mounting , sideways , upward
Storage Temperature (DegreeC)
-25 - +65
Input Frequency (Hz)
50/60Hz(47 - 450Hz)
higher Harmonics Current Regulation
EN61000-3-2 compatibility
Efficiency
More than 77%
Installation Method
Corresponding to DIN rail mounting
Power Factor
-
Input Variation Influence
0.5% or less (input AC85?264V 100% load)
Impact Resistance (m/s2)
150 (6 directions 3 times each, no abnormalities)
Insulation Resistance (Mohm)
100 or more (output bulk) and between ground [earth]) at DC500V
Output Current Display
Not available
Functions
Series operation: Possible (for up to 2 units, iexternal diode is required) parallel operation: impossible low voltage detection display: present (color, red)
Inrush Current (A)
During 100V input: below 25A during 200V input: below 50A (25deg C, cold start)
Safety Standards
UL:UL508(Listing, Class2 Output:Per 1310), UL1604(Class[I]/Division2), UL60950-1 cUL:CSA C22.2 No.14(Class2 Output), No213(Class[I]/Division2) cUR:CSA C22.2 No.60950-1 EN/VDE:EN50178(=VDE0160)
Starting Time (min)
Below 100 (at rated input/output )
Ambient Humidity
25-85% (preserved humidity 25?90%)
Alarm Output
SINK (EMITTER COM)
Vibration Resistance
10 To 55 Hz half amplitude of 0.375 mm 3 directions 2 h each ,without abnormality
Load Changes
1.5% or less (by a rated input and 0 to 100% load)
Withstand Voltage
AC3.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC2.0kV 1min (batch input)and (ground [earth]/ FG) between ( detection current20mA )) AC1.0kV 1min between(bulk output)and (ground[earth]/ FG) between (detection current of 20mA)
Temperature Fluctuation
0.05%/deg C or less
Terminal Block
Screw terminal block
Output Voltage Adjustable Range (%)
-10-+15(at V.ADJ )
Radiated Interference Field Intensity
EN61204-3 Class B compatibility
Outer Dimensions (Width W x Height H x Depth D) (mm)
22.5x85x96.4
Output Current (A)
0.65
Input Voltage (V)
AC100 - 240
Output Indicator
Available (color: Green)
Output Voltage (V)
24
Operating Ambient Temperature (deg C)
-10 - 60
Type
Standard type
Peak Hold Current Display
Not available
Output Ripple Noise Voltage
Below 2.0% (p-p) (at rated input and output)
Output Voltage Display
Not available
Leakage Current (mA)
During 100V input: less than 0.5 during 200V input : 1 or less
Over-Voltage Protection
Available (Zener diode clamp method) If the internal feeback circuit is damaged, the clamped voltage load may become damaged as well (about 140-190% of the rated output voltage).
Disturbance Voltage
EN61204-3 Class B conformity, FCC class A conformity
Overcurrent Protection
105 to 160% of the rated output current , droop form foldback and automatic recovery
Input Curret (A)
100 V input time: below 0.45 200V input time: below 0.25
Replacement
Not available
Under Voltage Detection Output
Not available
Output Holding Time
20 ms or more ( at rated input and output)
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
2 Customer Reviews
The reviews are automatic translation.
Practice kit for training
5
From Japan
On 2016-07-15 16:34:59
Because it is made by OMRON, it can be used without any problem. It is slightly expensive.
This review is about item#08591441.
Instrumentation power supply
5
From Japan
On 2014-06-23 09:04:27
Compact and easy to use
This review is about item#08591475.