NoteBuy more than* S$150* and get FREE SHIPPING

  • Switching Power Supply S8VS
  • Switching Power Supply S8VS
  • Switching Power Supply S8VS

Switching Power Supply S8VS S8VS-01524

5.00 (2)
Package Qty.
Ship pack of
78.55 SGD
In stock
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Operating Ambient Temperature (deg C)
-10 - 60
Weight (g)
160 Or less
Capacity (W)
Mounting Direction
Standard mounting , sideways , upward
Radiated Interference Field Intensity
EN61204-3 Class B compatibility
Input Frequency (Hz)
50/60Hz(47 - 450Hz)
Output Current (A)
Input Voltage (V)
AC100 - 240
Installation Method
Corresponding to DIN rail mounting
Output Holding Time
20 ms or more ( at rated input and output)
Input Variation Influence
0.5% or less (input AC85?264V 100% load)
Impact Resistance (m/s2)
150 (6 directions 3 times each, no abnormalities)
Peak Hold Current Display
Not available
Output Current Display
Not available
Output Voltage Display
Not available
Inrush Current (A)
During 100V input: below 25A during 200V input: below 50A (25deg C, cold start)
Safety Standards
UL:UL508(Listing, Class2 Output:Per 1310), UL1604(Class[I]/Division2), UL60950-1 cUL:CSA C22.2 No.14(Class2 Output), No213(Class[I]/Division2) cUR:CSA C22.2 No.60950-1 EN/VDE:EN50178(=VDE0160)
Starting Time (min)
Below 100 (at rated input/output )
Ambient Humidity
25-85% (preserved humidity 25?90%)
Alarm Output
Vibration Resistance
10 To 55 Hz half amplitude of 0.375 mm 3 directions 2 h each ,without abnormality
Load Changes
1.5% or less (by a rated input and 0 to 100% load)
Power Factor
Temperature Fluctuation
0.05%/deg C or less
Terminal Block
Screw terminal block
Output Voltage Adjustable Range (%)
-10-+15(at V.ADJ )
Storage Temperature (DegreeC)
-25 - +65
Outer Dimensions (Width W x Height H x Depth D) (mm)
higher Harmonics Current Regulation
EN61000-3-2 compatibility
More than 77%
Output Indicator
Available (color: Green)
Output Voltage (V)
Withstand Voltage
AC3.0kV 1min between(batch input)and (batch output)(detection current of 20mA) AC2.0kV 1min (batch input)and (ground [earth]/ FG) between ( detection current20mA )) AC1.0kV 1min between(bulk output)and (ground[earth]/ FG) between (detection current of 20mA)
Standard type
Insulation Resistance (Mohm)
100 or more (output bulk) and between ground [earth]) at DC500V
Output Ripple Noise Voltage
Below 2.0% (p-p) (at rated input and output)
Series operation: Possible (for up to 2 units, iexternal diode is required) parallel operation: impossible low voltage detection display: present (color, red)
Leakage Current (mA)
During 100V input: less than 0.5 during 200V input : 1 or less
Over-Voltage Protection
Available (Zener diode clamp method) If the internal feeback circuit is damaged, the clamped voltage load may become damaged as well (about 140-190% of the rated output voltage).
Disturbance Voltage
EN61204-3 Class B conformity, FCC class A conformity
Overcurrent Protection
105 to 160% of the rated output current , droop form foldback and automatic recovery
Input Curret (A)
100 V input time: below 0.45 200V input time: below 0.25
Not available
Under Voltage Detection Output
Not available
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
2 Customer Reviews
The reviews are automatic translation.
Training kit to be used in the training
From Japan
On 2016-07-15 16:34:59
Since Omron has been used without any problems. But it is a little high.
This review is about item#08591441.
Instrumentation of power supply
From Japan
On 2014-06-23 09:04:27
Easy-to-use compact
This review is about item#08591475.