NoteBuy more than* S$150* and get FREE SHIPPING

  • Switching Power Supply S8VS
  • Switching Power Supply S8VS
  • Switching Power Supply S8VS

Switching Power Supply S8VS S8VS-24024

5.00 (2)
Package Qty.
Ship pack of
329.90 SGD
Shipped after 2016-10-26
Now we ship to...
...see all
Item Feature
This product is manufactured in Japanese standards. Please check the specification before you order.
Input Frequency (Hz)
50/60Hz(47 to 63Hz)
More than 80%
Output Indicator
Yu (color: green)
Output Voltage (V)
Weight (g)
1150or less
Capacity (W)
Storage Temperature (DegreeC)
-25 to +65
Input Variation Influence
(At the load input AC85 to 264V 100%) 0.5% or less
Impact Resistance (m/s2)
(That there are no errors in each direction 3 times 6) 150
Peak Hold Current Display
Output Current Display
Output Voltage Display
Inrush Current (A)
(25 deg C, at cold start) 50A following : 100V input: 25A following 200V input
Safety Standards
UL: UL508 (Listing), UL60950-1cUL: CSA C22.2 No.107.1cUR: CSA No.60950-1EN / VDE: EN50178 (= VDE0160) EN60950-1 (= VDE0805 Teil1) Korea S mark
Starting Time (min)
1000 or less (at the rated input and output)
Ambient Humidity
25-85% (25-90% Storage humidity)
Alarm Output
Sink (emitter COM)
Vibration Resistance
And that there are no errors in the three directions of the 2h 10 to 55Hz single amplitude 0.375mm
Load Changes
(At rated input load, 0-100%) 1.5%
Withstand Voltage
(Input batch) (output batch, alarm output batch) between AC3.0kV 1min (detection current 20mA) AC2.0kV 1min (input batch) (ground [earth] / FG) between (detection current 20mA)) AC1.0kV (bulk output, alarm output batch) and 1min (ground [earth] / FG) between (detection current 30mA) AC500V 1min (output batch) (alarm output batch) between (detection current 20mA)
Outer Dimensions (Width W x Height H x Depth D) (mm)
higher Harmonics Current Regulation
EN61000-3-2 fit
Input Voltage (V)
AC100 to 240
Installation Method
It corresponds to the DIN rail mounting
Operating Ambient Temperature (deg C)
-10 to 60
Terminal Block
Screw terminal block
Mounting Direction
Standard mounting
Radiated Interference Field Intensity
EN55011Group1 ClassB fit
Standard type
Insulation Resistance (Mohm)
More than 100 (output batch, alarm output batch) (input bulk, ground [earth]) in between DC500V
Output Ripple Noise Voltage
2.0% (p-p) or less (at the rated input and output)
Series operation: Yes (up to two external diode required) parallel operation: No undervoltage detection table show: No
Leakage Current (mA)
100V Input: 0.5 or less 200V Input: 1.0 or less
Over-Voltage Protection
(Turn OFF the input power, at least three minutes, please cycle the input power is restored) Yu
Disturbance Voltage
EN55011Group1 ClassB fit, FCC compliance of Class A
Overcurrent Protection
105-160% of the rated output current, inverted L-shaped drooping, automatic return
Input Curret (A)
100V Input: 3.8 below 200V Input: 2.0 or less
Under Voltage Detection Output
Output Holding Time
20ms or more (at rated output)
Customer Reviews
5 star 2
4 star 0
3 star 0
2 star 0
1 star 0
Review Rating: 5.00
2 Customer Reviews
The reviews are automatic translation.
Training kit to be used in the training
From Japan
On 2016-07-15 16:34:59
Since Omron has been used without any problems. But it is a little high.
This review is about item#08591441.
Instrumentation of power supply
From Japan
On 2014-06-23 09:04:27
Easy-to-use compact
This review is about item#08591475.