A general-purpose pressure switch that is highly evaluated for its reliability and durability.
For air conditioning, air conditioning, and various industrial equipment
Operation Ambient Temperature (℃) -20~70 Fluid Temperature (℃) -20~120 RoHS directive (corresponding to 10 substances) Correspondence
Easy-to-read 3-color LCD display. Easy setting with up / down buttons. The buttons are large and easy to operate. The cable is a connector method and can be easily attached and detached. Equipped with switch output and analog output as standard. Energy saving.
Mass (g) Approx. 80 (including cable) Structure Silicon diaphragm Protection Class IP40 Suitable Fluid Air, non-corrosive, non-flammable gas Current Consumption (mA) 40 or less (with no load) Operation Indicator Lamp Orange (1 & 2 indicator) OUT1 OUT2 Repeatability (%) ± 0.2FS ± 1digit or less Withstand Voltage (V) AC10001 min (between lead wire and case)
Included Accessories PPX-C2 (2m connector cable) x 1 Mass (g) About 40 Protection Class IP40(IEC) Type of Connection Connector Operation Ambient Temperature (℃) -10 to +50, when stored / -10 to +60 Short Circuit Protection Equipment Hysteresis Minimum 1 digit (variable) Output Operation Select NO/NC by key operation Suitable Fluid Air / non-corrosive gas
Suitable Fluid Water Response Time Approximately 500ms (alarm output) Fluid Temperature (℃) 0 to +70 (however, without freezing) Withstand Pressure (MPa) 1.5 Mounting Side freedom Ambient Temperature (℃) 0 to +50 (However, no condensation) Flow direction Both directions Pressure range (MPa) 0~1.0
Single unit specifications for various general-purpose mounting
Protection Class IP65 equivalent Contact Configuration 1a Maximum Operating Pressure (MPa) 1 Load Voltage (V) DC12/24、AC100 Suitable Fluid Compressed air Lamp Light-emitting diode (lights up when ON) Pressure Setting Range (MPa) 0.1~0.6 Ambient and Flowing Fluid Temperature (℃) 5~60 Repeatability ± 0.02MPa or less Hysteresis (MPa) 0.08 or less Insulation Resistance 20MΩ or more at DC500V mega Load current (mA) 5~50、7~20 Voltage drop (V) 3 or less (internal)
Protection Class IEC standard IP40 equivalent Operating Pressure Range (MPa) 0~1 Operation Mode Analog output Withstand Pressure (MPa) 1.5 Display Part No pressure display Suitable Fluid Air, inert gas Current Consumption (mA) 20 mA or less (24 VDC no load) Type Positive pressure sensor RoHS directive (corresponding to 10 substances) Correspondence Power supply 10.8 to 30 VDC (including ripple)
It converts the pressure into the thrust of the piston and turns the micro switch on and off. A signal is output when the pressure of compressed air reaches the set pressure. (BN-1217T-6 is a reed switch type)
Protection Class IEC standard IP40 equivalent Display Part No pressure display Suitable Fluid Air, inert gas Current Consumption (mA) 20 mA or less (24 VDC no load) Type Negative pressure sensor RoHS directive (corresponding to 10 substances) Correspondence Power supply 10.8 to 30 VDC (including ripple)
Protection Class IEC standard IP40 equivalent Display Part No pressure display Suitable Fluid Air, inert gas Current Consumption (mA) 20 mA or less (24 VDC no load) Type Positive pressure sensor RoHS directive (corresponding to 10 substances) Correspondence Power supply 10.8 to 30 VDC (including ripple)
Contact Configuration 1ab Maximum Operating Pressure (MPa) 1.0 Shape of Switch Micro switch: Z-15GD-B (OMRON) Pressure Adjustment Range (MPa) 0.1~0.8 Suitable Fluid Compressed air Insulation Resistance (MΩ) 100 or more (at 500 VDC megger) Assured Pressure Resistance (MPa) 1.5 Ambient Humidity (% RH) 90 or less Fluid Temperature (℃) 5~60 Material (Body) Zinc die cast Mounting Direction Any Repeatability Within ± 0.020MPa against set pressure Allowable Operating Frequency (times / minute) 20 Ambient Temperature (℃) -5 ~ 60 ℃ (No freezing)
We have a lineup of products that support not only drive equipment but also pneumatic systems in detail, making them easier to use and expanding their applications. A small pressure switch for vacuum and positive pressure with excellent reliability and responsiveness. Easy operation with 2 screen... Read More
Operating Pressure Range (MPa) Low pressure type -0.10 to +0.10
Protection Class IEC standard IP40 equivalent Accuracy ±3%F.S.max.(at Ta=25℃) Display 0 to -99kPa (2-digit red LED display) Withstand Pressure (MPa) 0.2 Display Part With LED display Resolution 1digit Current Consumption (mA) 40 or less Display Format About 4 times / 1 second Humidity Range (RH) 35 to 85% (non-condensing) Display Accuracy ±3%F.S. ±2digit Detection Method Diffusion semiconductor pressure switch Pressure Setting Range (MPa) -99~0 Type Negative pressure sensor Operating Temperature (℃) 0-50 (no freezing) Working pressure range (kPa) -100~0 RoHS directive (corresponding to 10 substances) Correspondence Responsiveness 1m・sec max.
Protection Class IEC standard IP40 equivalent Operating Pressure Range (MPa) 0~1 Operation Mode NPN open collector output Withstand Pressure (MPa) 200 Display Part No pressure display Suitable Fluid Air, inert gas Current Consumption (mA) 20 mA or less (24 VDC no load) Type Negative pressure sensor RoHS directive (corresponding to 10 substances) Correspondence Power supply 10.8 to 30 VDC (including ripple)