Fluid Control Components
Other Related Pages
- CKD Direct Acting 2-Port Solenoid Valve (Multilex Valve) NC Pressurization AB31 / AB41 SeriesMultilex valve series that controls various types of fluids such as water, air, gas, and oil. * Please check the maximum operating pressure difference before selecting.Fluid Temperature (℃) -10 to 60 (no freezing) Ambient Temperature (℃) -20~60 Valve Seat Leakage (cm3/min) 0 (JIS leakage standard) Number of Ports 2 Withstand Pressure (MPa) 25 (water pressure) Maximum Operating Pressure (MPa) 5 Heat Resistance Class B Material (Body) Brass Type of Acting Direct acting Valve Structure Direct-acting poppet Coil Housing Grommet lead wire Material (Seal) Nitrile rubber Type of Thread Rc Mounting Direction freely
- CKD Pilot Kick Type 2-Port Solenoid Valve Open When Energized Multilex Valve ADK / APK SeriesMulti-flex valve series that controls various types of fluids such as water, air, gas, and oil. In addition to high reliability and high quality, we have a wide variety of options to surely improve the performance of various equipment and devices.Number of Ports 2 Type of Acting Pilot kick type Type of Thread Rc
- CKD Pilot Type 2-Port Solenoid Valve Open When Energized Multilex Valve AD / AP Series-Multi-flex valve series that controls various types of fluids such as water, air, gas, and oil. In addition to high reliability and high quality, we have a wide variety of options to surely improve the performance of various equipment and devices. Body: Bronze Seal: Nitrile rubber Coil housing: ... Read MoreNumber of Ports 2 Actuation Category Normally closed type Type of Acting Pilot type Type of Thread Rc
- CKD AB21 Series Multilex ValveType of Thread Rc Type of Acting Direct acting Lead Wire Length (mm) 250 Number of Ports 2
- CKD Direct Acting 2-Port Solenoid Valve NO/NC FAB SeriesValve Seat Leakage (cm3/min) 0.2 or less Maximum Operating Pressure (MPa) 1.4 Number of Ports 2 Withstand Pressure (MPa) 2.1 (at water pressure) Material (Body) ADC (aluminum die casting) Heat Resistance Class B Suitable Fluid Compressed air Type of Acting Direct acting Valve Structure Direct acting poppet structure Coil Grommet lead wire Material (Seal) NBR Actuation Category Open when energized (NC) Type of Thread Rc Mounting Direction freely
- CKD USB Series Compact Direct Acting 2-Port Solenoid ValveNumber of Ports 2 Type of Acting Direct acting
- CKD Pilot Operated 2-Port Solenoid Valve for Compressed AirIt contributes to energy saving with large flow rate and low power consumption.Ambient Temperature (℃) -5~55 Fluid Temperature (℃) 0 to 55 (no freezing) Range of Operating Pressure differential (MPa) 0.01~0.7 Number of Ports 2 Suitable Fluid Air Power Input (V) DC24 Rated Voltage (V) DC24 Type of Acting Pilot type
- CKD FWD series Pilot operated 2-port valve for waterAmbient Temperature (℃) -10 to 60 (no freezing of fluid) Range of Operating Pressure differential (MPa) 0.02~0.7 Maximum Operating Pressure (MPa) 0.7 Number of Ports 2 Fluid Temperature (℃) 5-60 (no freezing) Protection Class IPX5 Type of Switching NC (energization time) type Type of Thread Rc Mounting Direction freely
- CKD Direct Acting 3-Port Solenoid Valve Universal Type Multilex Valve AG SeriesMultilex valve series that controls various types of fluids such as water, air, gas, and oil.Fluid Temperature (℃) -10 to 60 (no freezing) Maximum Operating Pressure (MPa) 1 Number of Ports 3 Material (Body) Brass Type of Acting Direct acting Suitable for For air / water Coil Housing Grommet lead wire Material (Seal) Nitrile rubber Type of Thread Rc Actuation Category Universal type
- CKD PD3 Series Pulse Jet Valve Air operatedNumber of Ports 2 Type of Acting Pilot type Type of Thread Rc
- CKD USG series compact direct acting 3-port solenoid valveNumber of Ports 3 Suitable Fluid Air, water, dry air, low vacuum Type of Acting Direct actingfrom S$63.99Min. 2 days
- CKD Pilot operated 2-port solenoid valve for compressed air Compact air blow valve EXAAchieves large flow rate and low power consumption, small size and light weight, easy piping connectionAmbient Temperature (℃) -5~55 Fluid Temperature (℃) 0 to 55 (no freezing) Range of Operating Pressure differential (MPa) 0.01~0.7 Power Consumption (W) 0.6 Maximum Operating Pressure (MPa) 0.7 Withstand Pressure (MPa) 1.05 (at water pressure) Number of Ports 2 External leakage (cm 3 / min) 2 or less Internal leakage (cm 3 / min) 2 or less Dimension D (mm) 45 Dimension E (mm) 48.5 Dimension C (mm) 8 Heat Resistance Class B Suitable Fluid Compressed air Voltage (V) DC24 Rated Voltage (V) DC24 Material H-NBR (Seal) Protection Class Lead wire type: IPXO (IEC planning: 529) Type of Acting Pilot type Valve Structure Pilot type diaphragm drive Mounting Direction freely
- CKD Pilot Kick 2-Port Solenoid Valve Closed When Energized Multilex Valve ADK12 SeriesFluid Temperature (℃) -10 to 60 (no freezing) Ambient Temperature (℃) -10~60 Valve Seat Leakage (cm3/min) 0 (pneumatic 0.02-0.6MPa) Maximum Operating Pressure (MPa) 2 Number of Ports 2 Withstand Pressure (MPa) 4 (at water pressure) Heat Resistance Class B Driving System Diaphragm Coil Housing Grommet lead wire Actuation Category Normally open type Type of Acting Pilot kick type Type of Thread Rc Material (Body) bronze Mounting Direction freely
- CKD GSV Series 2 Port Solenoid Valve for Watering (Resin)Number of Ports 2 Type of Acting Pilot type
- CKD EXA Series Pilot Operated 2-Port Solenoid Valve for Compressed Air FlowNumber of Ports 2 Type of Acting Pilot type
- CKD SPK Series Steam Pilot Type 2 Port Solenoid ValveAmbient Temperature (℃) -10~60 Maximum Operating Pressure (MPa) 1.0 Number of Ports 2 Fluid Temperature (℃) 5~180 Type of Acting Pilot type Type of Thread Rc Suitable Fluid steamfrom S$249.90Min. 2 days
- CKD Pilot kick type 2-port piston drive valve Open when energized APK ・ ADKControls various fluids, various series variationsAmbient Temperature (℃) -10~60 Minimum Operating Pressure Differential (MPa) 0 Mass (kg) 0.7 Maximum Operating Pressure (MPa) 1 Maximum Operating Pressure Differential (MPa) 1 (steam) Orifice (mm) 12 Number of Ports 2 Withstand Pressure (MPa) 4 (at water pressure) Power Consumption (W) 50Hz:10、60Hz:8 Fluid Temperature (℃) 5~180 Material (Body seal) Body: Bronze, valve seal: PTFE Material (O-ring) Fluororubber Heat Resistance Class H Actuation Category Normally closed type Type of Acting Pilot kick type Type of Thread Rc
- CKD DSG series gas shut-off valve (quick open type)Pressure Resistance (MPa) 0.1 Operating Pressure Range (MPa) 0~5 Maximum Operation Frequency (times/min) 30 or less Suitable Fluid City gas, natural gas, LPG Maximum Operating Time (sec) Open: 0.5, Closed: 1.0 Type of Thread Rp
- CKD Pilot kick water 2-port valve PKW seriesSolenoid valve for general fluid (for water). We have a wide range of models depending on the fluid used, pressure, and diameter.Valve Seat Leakage (cm3/min) 0 (Water pressure 0.05 to 0.7 (0.5) MPa) Number of Ports 2 Fluid Temperature (℃) 5~60 Heat Resistance Class B Coil Open frame lead wire coil Type of Acting Pilot kick type Suitable Fluid Water Material (Body) bronze
- CKD ADK11 Series + Parts for Multirex ValveNumber of Ports 2 Type of Acting Pilot kick type Type of Thread Rc Pipe Connection Diameter Rc1/2 Type partsfrom S$45.99Min. 2 days
- CKD MYB series Metal-free 2-port valve for chemicalsWithstand Pressure (MPa) 0.3 (at water pressure) Number of Ports 2 Fluid Temperature (℃) 5~60from S$97.99Min. 13 days
- CKD Direct acting 2-port solenoid valve (Multilex valve) NO (closed when energized) type AB42 seriesMultilex valve series that controls various types of fluids such as water, air, gas, and oil.Maximum Operating Pressure Differential (MPa) (Air, water, kerosene, oil) 0.15 Fluid Temperature (℃) -10 to 60 (no freezing) Ambient Temperature (℃) -20~60 Valve Seat Leakage (cm3/min) 0 (JIS leakage standard) Mass (kg) 0.50 Cv Value 1.0 Connection: Rc (Tapered Thread for Pipe, Female) 1/4 Dimension C (mm) 12 Number of Ports 2 Maximum Operating Pressure (MPa) 2 (1 for fluid / steam) Effective Section Area (mm2) 21.1 Withstand Pressure (MPa) 25 (at water pressure) Dimension B (mm) 28 Dimension A (mm) 40 Power Consumption (W) 50Hz/8.7
60Hz/6.7 Orifice (mm) 7.0 Dimension D (mm) 75 Dimension E (mm) 97 Rated Voltage (V) AC100 Heat Resistance Class B Material (Body) Brass Type of Acting Direct acting Valve Structure Direct-acting poppet Coil Housing Grommet lead wire Material (Seal) Nitrile rubber Type of Thread Rc Mounting Direction freely - CKD PKS series pilot kick type 2 port valveNumber of Ports 2 Type of Acting Pilot kick typefrom S$47.99Min. 17 days
- CKD ADK11 Series Multi-Rex Valve (Pilot Kick Type 2-Way Valve)Number of Ports 2 Type of Acting Pilot kick type
- CKD PDV3 Series Pulse Jet Valve Solenoid ValveNumber of Ports 2 Type of Acting Pilot type Type of Thread Rcfrom S$64.99Min. 17 days
- CKD Diaphragm assemblyNumber of Ports 2 Pipe Connection Diameter 3/4 Suitable Model AD-20A Type of Acting Pilot type Type of Thread Rc Type partsfrom S$45.99Min. 2 days
- CKD AP11 Series Multi-Rex Valve (Pilot 2-Way Valve)Type of Acting NC (open when energized)from S$11.99Min. 2 days
- CKD AD11 Series Multi-Rex Valve (Pilot Type 2-Way Valve)Type of Acting Pilot type Valve Structure Piloted poppet structure Diaphragm drivefrom S$11.99Min. 2 days
- CKD ABP series air boosterBy combining with an air tank without using electricity, it is possible to increase the pressure up to twice the temporary pressure (up to 0.99 MPa) only with air pressure. It is possible to increase the pressure only in the necessary places in the factory, and it is possible to save energy and c... Read More
- CKD Rain sensorIt is a rain sensor dedicated to the controller. Automatically detects rain of 6 mm or more.Mass (kg) 0.4 Rainfall (mm) (Operation) 6 Specification No power supply required Width (mm) 138 Height (mm) 83.5 Trusco Part No. 376-8724from S$199.90Min. 2 days
- CKD Pilot Kick Type 2-Port Diaphragm Drive Valve NO/NC APK/ADKControls various fluids, various series variationsFluid Temperature (℃) -10 to 60 (no freezing) Ambient Temperature (℃) -10~60 Minimum Operating Pressure Differential (MPa) 0 Number of Ports 2 Maximum Operating Pressure (MPa) 2 Coil Housing 2G Withstand Pressure (MPa) 4 (at water pressure) Heat Resistance Class B Material (Body seal) Body: Bronze, Valve seal: Nitrile rubber Type of Acting Pilot kick type Type of Thread Rc Mounting Direction freely
- CKD ADK21 series multi-rex valve (pilot kick type two-way valve)Number of Ports 2 Type of Acting Pilot kick typefrom S$11.99Min. 13 days
- CKD Solenoid valve for airSolenoid valve for general fluid (for air, water, steam) We have a wide range of models in terms of fluid used, pressure, and diameter.Maximum Operating Pressure Differential (MPa) 0.7 Operating Pressure (MPa) 0~0.7 Number of Ports 2 Type of Acting Pilot kick type Type of Thread Rcfrom S$199.90Min. 2 days